Laserfiche WebLink
DIRECTOR <br />C'rai~ (.) [uedeman <br /> <br />BUILDING INSPECTION <br />(S()3/ 588-5~47 <br /> <br />PLANNING & <br />ENFORCEMENT <br />(S03) 588-5038 <br /> <br />IIOARD OF <br />COMMISSIONERS <br />Randall Franke <br />Gary [ leer <br />Mary Pparmine <br /> <br />ADMINISTRATIVE <br />OFFICER <br /> <br />Marion County <br /> <br /> OREGON <br />COMMUNITY DEVELOPMENT <br />DEPARTMENT <br /> <br />pLAN REVIEW NOTICE <br /> <br />DATE: <br /> <br />February 26, 1995 <br /> <br />$1/~JECT: <br /> <br />Del Mesa Farms Feed Mill Addition <br />(Formerly Belozer Poultry Farms) <br /> <br />OWNER: <br /> <br />CONTROL NL~4BER: 95-47 <br />PERMIT ~]/J'IMBER: 61042 <br />TYPE OF CONSTRUCTIO~. <br /> 5-N <br /> <br />BUILDIN~ CLA~S: <br /> <br />B-~ (Manufacturing) <br />Existing: 8,750 sq. <br />Addn.: 1,640 sq. ft. <br /> (2 yards @ 80'+) <br /> <br />The plans for the above indicated project are acceptable as submitted <br />subject to the following items noted below: <br /> <br />This is a Plan Review covering the construction of the above 1,640 sq. <br />warehouse/boiler/maint, shop addition to the existing building. This review <br />is for compliance with the provisions of the Oregon State Structural Specialty <br />Code ('91 UBC) 1993 Edition. <br /> <br />This review is not intended to prohibit the building inspector from requesting <br />an evaluation of the acceptability of existing structural members that may <br />appear to be unsafe. Existing construction not specifically detailed in the <br />plans and structural calculations is beyond the scope of this review. <br /> <br />The plans s~bmitted do not show enough information for a structural plan <br />review of the pre-engineered metal building. Submit structural plans <br />and calculations that show frame dimensions (member depth, plata width <br />and thickness, etc.) and connection details. Include en~wall details <br />and X-bracing_ <br />(W = 41'; L = 40'; H = ?'; BAY ~ 19') <br />(SNOW = 2S PSF; WIXTD = 80 MPH Exp. C) <br /> <br />A one-hour fire-resistive occupancy separation is required between the <br />boiler area and the shop/warehouse area. Ail openings in the separation <br />shall be protected by a fire assembly having a one-hour fire-protection <br />rating_ (803(d) Table NO. 5-~) <br /> <br />Fire doors, fire windows and fire dampers shall have a factory applied <br />label or other identification showing the fire protection rating. <br />(4306 (c)) <br /> <br />Warehouses and factories or workshops using materials not highly <br />flammable or combustible are classified as Group B Division 2 <br />Occupancies (B-2). Based on the limited information submitted with the <br />plans, this building has been classed as a B-2 Occupancy. The use or <br /> <br />Community Development Center · 285 Church Street N.E., Room 132 · Salem, Oregon 97301-3670 <br /> <br /> <br />