520 8TH ST~ AUMSVILLE <br />January 4, 1995 <br />Page 2 <br /> <br />This house plan uses a combination of Brace Panels (BP) and Alternate <br />Brace Panels (ABP) to met ~ c~de r.e~.re~ent~ for lateral wall <br />bracing. Insure that all B~'~ a~d AB~'~'ar~ lo~ated as indicated <br />on the plans and construct%d as'~ow~.'. '.. <br /> <br />In scissor trusses loose fill insulation is not allowed when there is <br />less than 44 inche~ of headroom and/or the interior ceilim~ ~loDe <br />exceeds 2 in 12. <br /> <br />10. <br /> <br />Any ceiling is considered vaulted when the ceiling slope is 2/12 or <br />greater. Insulation in a flat ceiling (slope less than 2/~2) shall have <br />a minimum rating of R-38. Insulation in vaulted ceilings may have a <br />minimum rating of R-30, for a maximum of 50% of the total heated floor <br />space area. (Oregon Energy code) <br /> <br />THE FoLLOWIN~ ITEMS WER~ ADDED/CLARIFIED IN A PHONE CONVERSATION WITH HILL <br /> <br /> ENERGY PATH SHALL BE PATH 1 <br /> <br /> 2 ABP'S ~ BBIN~ ADDED TO THE FRONT OF THE GARAGE FOE LATERAL BRACING. <br /> (DOOR SIZE WILL B~ SMALLER) <br /> <br />13. 8' OF THH HACK WALL OF THE GA~AG~ IS B~ING USED AS A GYPSUM BRACE PANEL, <br /> ALL EDGES OF THE GYPSUM PANEL SHALL BE BLOCKED IN THIS 8' AREA. (ONE <br /> SIDE OF WALL ONLY) <br /> <br />Approval as a result of this plan review or an inspection shall not be <br />construed to be an approval of a violation of the provisions of the dwelling <br />code or of other ordinances of the jurisdiction. Reviews or inspections <br />presuming to give authority to violate or cancel the provisions of the <br />dwelling code or of other ordinances of the jurisdiction shall not be valid. <br /> <br />DAW <br /> <br />"APPROVED" only when this sheet is attached to plans <br /> <br /> <br />