Laserfiche WebLink
2010 Oregon Manufactured Dwelling Installation Specialty Code <br /> CHAPTER 4 4-3 Foundation Walls. <br /> UNDER-FLOOR ENCLOSURES 4-3.1. Foundation walls may be used in place of <br /> ` 4-1 General. recessed perimeter piers, skirting, marriage line <br /> 4-1.1. All manufactured dwellings shall have the column support piers under the end walls, <br /> under-floor area enclosed with skirting installed anchoring, and to support the horizontal <br /> according to this code. Skirting is not required pressures of backfill around the manufactured <br /> for manufactured dwellings installed in flood dwelling. Foundation walls shall be constructed <br /> hazard areas. according to this code and where not specific, to <br /> the Oregon Residential Specialty Code. <br /> 4-2 Skirting Material. Concrete based foundation walls can hold up to <br /> 4-2.1. Skirting shall be constructed of a durable 48 in. of backfill. Lumber framed foundation <br /> rigid material such as painted wood, exterior walls can hold up to 36 in. of backfill. <br /> grade wood composites, exterior grade plywood, 4-3.2. Foundation walls, when used, shall be <br /> vinyl, aluminum, steel, foam, masonry, cement constructed according to the following and <br /> board, concrete or other material acceptable to Figures 4-3.2(a), 4-3.2(b) and 4-3.2(c): <br /> the building official. (1) Foundation walls shall be constructed of <br /> 4-2.2. Skirting shall meet the following: poured-in-place concrete, concrete masonry <br /> (1) Skirting materials shall be manufactured and units (CMUs), foundation grade lumber, <br /> intended for exterior use. insulated concrete forms, or an approved or <br /> (2) Non-structural skirting shall not be used to listed prefabricated perimeter foundation wall <br /> support any loads except as necessary to system. <br /> carry its own weight and to resist the (2) A minimum 6 in. thick, continuous concrete <br /> elements. footing, not less than 12 in. wide reinforced <br /> (3) Skirting shall be self-supporting but may be with two continuous minimum #4 <br /> attached to the bottom of the manufactured reinforcement rods. Rods shall be lapped 12 <br /> 411/ dwelling floor for stability. in., connected with wire ties or equal, be 3 in. <br /> (4) Skirting shall be adequately secured to from the bottom of the footing, and not closer <br /> assure stability and to minimize vibration and than 3 in. from the edge of the footing. <br /> susceptibility to wind damage. (3) Foundation walls shall provide a tight fit to <br /> (5) Skirting shall be installed to compensate for the bottom of the manufactured dwelling <br /> possible frost heave and settling but is not floor framing. Shimming may be permitted <br /> required to have a footing located at or between outriggers and other permanent <br /> below the frost line. obstructions. <br /> (6) Holes or gaps below the skirting shall be (4) Foundation walls or footings shall be <br /> sealed to resist air and water infiltration. secured to the manufactured dwelling. <br /> (7) Skirting shall be designed to resist the (5) The stand shall be a minimum of 12 in. <br /> entrance of moisture and rodents into the above the base flood elevation (BFE) <br /> under-floor area. according to the Flood Insurance Rate Map <br /> (FIRM) unless the foundation wall is opened <br /> (8) Skirting transitions between the skirting and on one side or end so that floodwater cannot <br /> the bottom of the home shall be attached in be trapped. <br /> a manner that does not trap water between (6) All under-floor enclosures that retain over 8 <br /> the skirting and the home siding or trim. in. of backfill and where ground water may <br /> (9) The transition from the siding on the home to present a detrimental condition, one or more <br /> the skirting shall be weather sealed to of the following must be done and the <br /> prevent water migration behind the transition building official shall require any or all of the <br /> board or into the crawl space. following: <br /> (10) All under-floor enclosures that retain over 8 (a) Foundation walls water proofed around the <br /> L in. of backfill must be water proofed below perimeter of the manufactured dwelling; <br /> �/ grade around the perimeter of the home. (b) A perimeter drain around the foundation wall <br /> to divert water away from the manufactured <br /> dwelling; or <br />