My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12985313
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
13-XXXXX
>
12985313
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/29/2025 8:00:14 PM
Creation date
7/29/2025 3:44:59 PM
Metadata
Fields
Template:
Permits
Permit Address
750 GRICE LP S
Permit City
Jefferson
Permit Number
555-13-02501
Parcel Number
103W12CC12300
Permit Type
Revision
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2010 Oregon Manufactured Dwelling Installation Specialty Code <br /> • Table 3-7.4 Pier Spacing <br /> 1,000 PSF 1,250 PSF 1,500 PSF 2,300 PSF Concrete <br /> (L Pier Spacing Soil Capacity Soil Capacity Soil Capacity Runner or Slab <br /> tier Main Frame Piers 4 ft.—6 in. 5ft.-6 in. 6 ft.—O in. 8ft.-0 in. --- <br /> Perimeter Sidewall Piers 4ft.-6 in 5ft.-6 in. Eft.-6 in. 8ft.—O in. <br /> Marriage Line Wall Piers 4ft. —6 in. 5ft.—6 in. 6 ft.—6 in. 8ft.—0 in. <br /> Marriage Line Floor Piers 8ft.—0 in. 8ft.—0 in. 8ft.—0 in. 8ft.—0 in. <br /> NOTES: <br /> (1) Pier spacing is based on 256 square inch footings. <br /> (2) Perimeter piers are required at both sides of all doors and at any opening 4 ft.wide or greater. <br /> (3)This table applies to the initial installation of homes having floors that are 14 ft. wide or less. Homes <br /> with floors over 14 ft. wide shall be installed according to the manufacturer's installation instructions. <br /> (4) For all secondary installations, piers shall be spaced according to this table. <br /> (5) Perimeter piers are required on all homes, except when the distance from the I-beam to the perimeter <br /> of the home is less than 16 in. <br /> 3-7.5 Concrete Block Pier Configuration. (1) 1 in. thick group 2 or 3 parallel laminated <br /> 3-7.5.1. Concrete block piers shall be installed in veneer wood plate; <br /> accordance with the following: Figure 3-7.2. (2) 1/4 in. or greater plywood; <br /> (1) The concrete blocks shall be stacked with (3) One 1-1/2 in. thick S-P-F (Spruce-Pine-Fir) <br /> their hollow cells aligned vertically. or better board lumber free of loose knots, <br /> (2) When piers are constructed of blocks splits, or other visual defects; <br /> stacked side by side, each layer shall be at (4) 3/4 in. thick S-P-F (Spruce-Pine-Fir)or better <br /> fir' right angles to the preceding one. board lumber free of loose knots, splits, or <br /> 3-8 Pier Caps, Shims and Wedges. other visual defects; <br /> 3-8.1 Pier Caps. Structural loads shall be evenly (5) 1-1/4 in. minimum thick wood polymer <br /> distributed across capped hollow block piers. composite; <br /> Material shall be equal in size to the pier blocks. (6) 4 in. x 6 in. wood beam; <br /> Piers shall be constructed from one of the (7) Listed and approved shimming material; or <br /> following: (8) Material or methods designed by a <br /> (1) A 4 in. nominally thick solid concrete block; registered design professional and approved <br /> (2) A 1 in. nominally thick group 2 or 3 parallel by the building official. <br /> laminated veneer wood plate; 3-8.3 Wedges. Wedges for CMU block <br /> (3) One piece of 1-1/4 in. plywood; foundation piers shall be made with one of the <br /> (4) Two pieces of 3/4 in. plywood; following materials, but shall not exceed a <br /> combined height of 9 in.: <br /> (5) One 1-1/2 in. thick S-P-F (Spruce-Pine-Fir) (1) Two sets of 3/4 in. thick by 3-1/2 in. wide by <br /> or better board lumber free of loose knots, gin. to 16 in. long wood wedges; <br /> splits, or other visual defects; <br /> (6) One 1-1/2 in. thick wood polymer composite; (2) One set of 1-1/2 in. thick by 3-1/2 in. wide by <br /> 8 in. to 16 in. long wood wedges; <br /> (7) Listed and approved prefabricated pier caps; (3) Listed or approved shimming material; or <br /> or <br /> (8) Material or methods designed by a (4) Material or methods designed by a <br /> registered design professional and approved registered design professional and approved <br /> by the building official. the building official. <br /> c3-8.2 Pier Shims. Pier shims for CMU block 3-9 Perimeter Piers. <br /> foundation piers shall be a minimum of 5-1/2 in. 3-9.1 Perimeter Piers. Perimeter piers may be <br /> x 16 in. constructed using any of the following recessed under the sidewalls, up to 12 in., to <br /> materials, but shall not exceed a combined allow room for skirting to be constructed or <br /> height of 9 in.: installed. When foundation walls, basement <br />
The URL can be used to link to this page
Your browser does not support the video tag.