Laserfiche WebLink
2010 Oregon Manufactured Dwelling Installation Specially Code <br /> issues that arise, subject to the approval of the accessibility, life and fire safety, or structural <br /> appointing authority. requirements. The details of the action granting <br /> liip, 1-3.5 Right of Entry. Where it is necessary to modifications shall be recorded and entered in <br /> make an inspection to enforce the provisions of the files of the department of building safety. <br /> this code, or where the building official has 1-3.9 Alternative Materials, Design and <br /> reasonable cause to believe that there exists in Methods of Construction and Equipment. <br /> a manufactured dwelling or upon a premises a The provisions of this code are not intended to <br /> condition which is contrary to or in violation of prevent the installation of any material or to <br /> this code which makes the manufactured prohibit any design or method of construction <br /> dwelling or premises unsafe, dangerous or not specifically prescribed by this code, provided <br /> hazardous, the building official is authorized to that any such alternative has been approved. An <br /> enter the manufactured-dwelling-or premises atalternative material,- design -or method---of- - <br /> reasonable times to inspect. If the manufactured construction shall be approved where the <br /> dwelling or premises is occupied, identification building official finds that the proposed design is <br /> shall be presented to the occupant and entry satisfactory and complies with the intent of the <br /> requested. If the manufactured dwelling or provisions of this code, and that the material, <br /> premises is unoccupied, the building official shall method or work offered is, for the purpose <br /> first make a reasonable effort to locate the intended, at least the equivalent of that <br /> owner or other persons having charge or control prescribed in this code in quality, strength, <br /> of the manufactured dwelling or premises and effectiveness, fire resistance, durability and <br /> request entry. If entry is refused, the building safety. For the process governing alternate <br /> official shall have recourse to the remedies method rulings acceptable statewide, see ORS <br /> provided by law to secure entry. 455.060. <br /> 1-3.6 Department Records. The building official ORS 455.060 is not part of this code but is <br /> shall keep official records as dictated by OAR reproduced here for the reader's convenience: <br /> 166-150-0020 where a county has jurisdiction, 455.060 Rulings on acceptability of material, design <br /> OAR 166-200-0025 where a city has jurisdiction, or method of construction; effect of approval. (1) <br /> and OAR chapter 166, division 300 where the Any person who desires to use or furnish any material, <br /> State of Oregon has jurisdiction. Such records design or method of construction or installation in the <br /> shall be retained in the official records for the state, or any building official, may request the Director <br /> period indicated in the respective OARS noted of the Department of Consumer and Business Services <br /> above. The building official shall maintain a to issue a ruling with respect to the acceptability of any <br /> permanent record of all permits issued in flood material, design or method of construction about which <br /> there is a question under any provision of the state hazard areas, including copies of inspection <br /> reports and certifications required in Section 1- building code.Requests shall be in writing and, if made <br /> r 8 by anyone other than a building official, shall be made <br /> and the ruling issued prior to the use or attempted use of <br /> 1-3.7 Approved Materials and Equipment such questioned material,design or method. <br /> Materials, equipment and devices approved by (2) In making rulings, the director shall obtain the <br /> the building official shall be constructed and approval of the appropriate advisory board as to <br /> installed in accordance with this approval. The technical and scientific facts and shall consider the <br /> use of used materials which meet the standards and interpretations published by the body that <br /> requirements of this code for new materials is Promulgated any nationally recognized model code <br /> adopted as a specialty code of this state. <br /> permitted. (3) A copy of the ruling issued by the director shall <br /> 1-3.8 Modifications. Wherever there are be certified to the person making the request. Additional <br /> practical difficulties involved in carrying out the copies shall be transmitted to all building officials in the <br /> provisions of this code, the building official shall state. The director shall keep a permanent record of all <br /> have the authority to grant modifications for such rulings, and shall furnish copies thereof to any <br /> individual cases, upon application of the owner interested person upon payment of such fees as the <br /> or owner's representative. The building official director may prescribe. <br /> shall first find that special individual reasons (4)A building official or inspector shall approve the <br /> Mlle use of any material, design or method of construction <br /> make the strict letter of this code impractical and approved by the director pursuant to this section if the <br /> the modification Is in compliance with the intent requirements of all ether local ordinances are satisfied. <br /> and purpose of this code, and that such 1-3.10 Tests. Whenever there is evidence of <br /> modification does not lessen health, non-compliance with the provisions of this code, <br />