My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12986842
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
12-XXXXX
>
12986842
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2025 8:00:11 PM
Creation date
7/30/2025 11:57:10 AM
Metadata
Fields
Template:
Permits
Permit Address
16829 ABIQUA RD NE
Permit City
Silverton
Permit Number
555-12-00311
Parcel Number
061E20C 00601
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRE AND SMOKE PROTECTION FEATURES <br /> SE 1�`.,. accordance with Section 715.4.5. Fire door assemblies and <br /> _,. . "Ni,e ES shutters shall be installed in accordance with the provisions of <br /> 715.1 General.Opening protectives required by other sections this section and NFPA 80. <br /> of this code shall comply with the provisions of this section. Exceptions: <br /> 715.2 Fire-resistance-rated glazing. Fire-resistance-rated 1. Labeled protective assemblies that conform to the <br /> glazing tested aspart of a fue-resistance-rated wall assembly in requirements of this section or UL WA,UL 14B and <br /> accordance with ASTM E 119 or UL 263 and labeled in accor- UL 14C for tin-clad fire door assemblies. <br /> dance with Section 703.5 shall be permitted in fire doors and 2. Floorfire door assemblies in accordance with Section <br /> fire window assemblies in accordance with their listings and 712.8. <br /> shall not otherwise be required to comply with this section. <br /> 715.3 Alternative methods for determining fire protection 715.4.1 Side-hinged or pivoted swinging doors.Fire door <br /> assemblies with side-hinged and pivoted swinging doors <br /> ratings. The application of any of the alternative methods shall be tested in accordance with NFPA 252 or UL IOC. <br /> listed in this section shall be based on the fire exposure and After 5 minutes into the NFPA 252 test,the neutral pressure <br /> acceptance criteria specified in NFPA 252,NFPA 257 or UL 9. level in the furnace shall be established at 40 inches(1016 <br /> The required fire resistance of an opening protective shall be mm)or less above the sill. <br /> permitted to be established by any of the following methods or <br /> procedures: 715.4.2 Other types of assemblies. Fire door assemblies <br /> 1. Designs documented in approved sources. with other types of doors,including swinging elevator doors <br /> and fire shutter assemblies, shall be tested in accordance <br /> 2. Calculations performed in an approved manner. with NFPA 252 or UL 10B.The pressure in the furnace shall <br /> be maintained as nearly equal to theatmospheticpressnre as 3. Engineering analysis based on a comparison of opening <br /> possible.Onceestablished,the pressure shall be maintained protective designs having fire protection ratings as <br /> determined by the test procedures set forth in NFPA 252, during the entire test period. <br /> NFPA 257 or UL 9. 715.4.3 Door assemblies in corridors and smoke barri- <br /> 4. Alternative protection methods as allowed by Section ers.Fire door assemblies required to have a minimum fire <br /> 104.11. protection rating of 20 minutes where located in corridor <br /> 47 I walls or smoke barrier walls having afire-resistance rating <br /> 715.4 Fire door and shutter assemblies.Approved fire door in accordance with Table 715.4 shall be tested in accordance <br /> and fire shutter assemblies shall be constructed of any material with NFPA 252 or UL l OC without the hose stream test. <br /> or assembly of component materials that conforms to the test <br /> requirements of Section 715.4.1,715.4.2 or 715.4.3 andthefire Exceptions: <br /> protection rating indicated in Table 715.4. Fire door frames I. Viewports that require a hole not larger than 1 inch <br /> with transom lights, sidelights or both shall be permitted in (25 nun)in diameter through the door,have at least <br /> TABLE 715.4 <br /> FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION RATINGS <br /> REQUIRED ASSEMBLY RATING MINIMUM FIRE DOOR AND FIRE 1 <br /> TYPE OF ASSEMBLY (hours) SHUTTER ASSEMBLY RATING(hours) <br /> 4 <br /> Fire walls and fire barriers having a required fire-resistance 3 3' <br /> rating treater than I hour 2 1'/2 <br /> 1'/2 11/2 <br /> Fire barriers having a required fire-resistance rating of I hour: <br /> Shaft exit enclosure and exit passageway walls 1 1 <br /> Fire partitions: <br /> Corridor walls ) I/3 b <br /> 0,5 I/r b <br /> Other fire partitions 1 3/ <br /> 0.5 I/3 - <br /> 3 142 <br /> I;Exterior walls 2 11/2 <br /> 4 - 1 3/4 <br /> v (Smoke barriers 1 I/ b <br /> a. aWo doors,each with a fire protection rating of IV,hours,installed on opposite sides ofthesame opening in afire wail,shell be deemed equivalent in fire protection <br /> rating to one 3-hour 5re door. <br /> b-For testing requirements,see Section 715.4.3- <br /> 120 2010 OREGON STRUCTURAL SPECIALTY CODE <br />
The URL can be used to link to this page
Your browser does not support the video tag.