My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12986842
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
12-XXXXX
>
12986842
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2025 8:00:11 PM
Creation date
7/30/2025 11:57:10 AM
Metadata
Fields
Template:
Permits
Permit Address
16829 ABIQUA RD NE
Permit City
Silverton
Permit Number
555-12-00311
Parcel Number
061E20C 00601
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRE AND SMOKE PROTECTION FEATURES <br /> 715.4.7.2 Exit and elevator protectives. Approved I. Doors installed across a corridor. <br /> fire-protection-rated glazing used in fire door assemblies 2. Doors that protect openings in exits or corridors <br /> in elevator and exit enclosures shall be so located as to required to be of fire-resistance-rated construc- <br /> furnish clear vision of the passageway or approach to the lion. <br /> elevator,ramp or stairway. <br /> 3. Doors that protect openings in walls that are <br /> 715.4.7.3 Labeling. Fire-protection-rated glazing shall capable of resisting the passage of smoke in <br /> bear a label or other identification showing the name of accordance with Section 508.2.5.2. <br /> the manufacturer, the test standard and information <br /> required in Section 715.5.9.1 that shall be issued by an 4. Doors installed in smoke barriers in accordance <br /> approved agency and shall be permanently affixed to the with Section 710.5. <br /> glazing. 5. Doors installed in fire partitions in accordance <br /> 715.4.7.3.1 Identification. For fire protection-rated with Section 709.6. <br /> glazing, the label shall bear the following four-part 6. Doors installed in a fire wall in accordance with <br /> identification:"D-H orNH-T or NT-XXX."D" Section 706.8. <br /> indicates that the glazing shall be used in fire door 7. Doors installed in shaft enclosures in accordance <br /> assemblies and that the glazing meets the fire protec- with Section 708.7. <br /> tion requirements of NFPA 252. "H" shall indicate 8. Doors installed in refuse and laundry chutes and <br /> that the glazing meets the hose stream requirements of �' <br /> NFPA 252. "NH"shall indicate that the glazing does access and termination rooms in accordance with <br /> not meet the hose stream requirements of the test."T" Section 708.13. <br /> shall indicate that the glazing meets the temperature 9. Doors installed in the walls for compartmentation <br /> requirements of Section 715.4.4.1. "NT" shall indi- of underground buildings in accordance with Sec- <br /> cate that the glazing does not meet the temperature tion 405.4.2. <br /> requirements of Section 715.4.4.1. The placeholder 10. Doors installed in the elevator lobby walls of <br /> "XXX" shall specify the fire-protection-rating underground buildings in accordance with Sec- <br /> period, in minutes. tion 405.4.3. <br /> 715.4.7.4 Safety glazing.Fire-protection-rated glazing 11. Doors installed in smoke partitions in accordance <br /> %aI installed m fire doors in areas subject to human impact in with Section 711.5.3. <br /> hazardous locations shall comply with Chapter 24. <br /> 715.4.8.4 Doors in pedestrian ways.Vertical sliding or <br /> • <br /> vertical rolling steel fire doors in openings through <br /> which pedestrians travel shall be heat activated or acti- <br /> Exceptions: vated by smoke detectors with alarm verification. <br /> I. Fire doors located in common walls separating 715.4.9 Swinging fire shutters.Where fire shutters of the <br /> sleeping units in Group R-I shall be permitted swinging type are installed in exterior openings, not less <br /> without automatic-or self-closing devices. than one row in every three vertical rows shall be arranged to <br /> 2. Theelevator car doors and the associated hoistway he readily opened from the outside, and shall be identified <br /> enclosure doors at the floor level designated for by highuishing marks or letters not less than 6 inches(152 <br /> mm)high. <br /> recall in accordance with Section 3003.2 shall be <br /> permitted to remain open during Phase 1 emer- 715.4.10 Rolling fire shutters.Where fire shutters of the <br /> gency recall operation. rolling type are installed, such shutters shall include <br /> approved automatic closing devices. <br /> 715.4.8.1 Latch required.Unless otherwise specifically x to ; ., <br /> permitted, single fire doors and both leaves of pairs of - d - ( +lazing in fire window <br /> side-hinged swinging fire doors shall be provided with assemblies shall be fire-protection rated in accordance with this <br /> an active latch bolt that will secure the door when it is section and Table 715.5. Glazing in fire door assemblies shall <br /> closed. comply with Section 715.4.7.Fire-protection-rated glazing shall <br /> be tested in accordance with and shall meet the acceptance crite- <br /> 715.4.8.2 Automatic-closing fire door assemblies. ria of NFPA 257 or UL 9.Fire-protection-rated glazing shall also <br /> Automatic-closing fire door assemblies shall be comply with NFPA 80. Openings in nonfire-resistance-rated <br /> self-closing in accordance with NFPA 80. exterior wall assemblies that require protection in accordance <br /> 715.4.8.3 Smoke-activated doors. Automatic-closing with Section 705.3, 705.8, 705.8.5 or 705.8.6 shall have a <br /> doors installed in the following locations shall be auto- fife-protection rating of not less than 3/4 hour. <br /> matic-closing by the actuation of smoke detectors Exceptions: <br /> installed in accordance with Section 907.3 or by loss of <br /> power to the smoke detector or hold-open device.Doors 1. Wired glass in accordance with Section 715.5.4. <br /> that are automatic-dosing by smoke detection shall not 2. Fire protection-rated glazing in 0.5-hour fire-resis- <br /> have more than a 10-second delay before the door starts tance-rated partitions is permitted to have an <br /> to close after the smoke detector is actuated: 0.33-hour fire-protection rating. <br /> 122 2010 OREGON STRUCTURAL SPECIALTY CODE <br />
The URL can be used to link to this page
Your browser does not support the video tag.