My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12987539
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
17-XXXXXX
>
12987539
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2025 8:00:12 PM
Creation date
7/30/2025 4:41:38 PM
Metadata
Fields
Template:
Permits
Permit Address
13773 SILVER FALLS HWY SE
Permit City
Sublimity
Permit Number
555-17-005840-STR
Parcel Number
081W14 00600
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TFP37O <br /> Page 4 of 12 <br /> LWhere gasketed grooved type a 25 sprinkler minimum design area,5 the hydraulically remote area, more <br /> couplings are being utilized,the gasket sprinklers on 5 branchlines are to be water pressure will likely be available <br /> ` I type must be capable of closing off calculated. For a 30 sprinkler design to these sprinklers than to sprinklers <br /> the gap between the pipe ends, e.g., area,5 sprinklers on 6 branchlines are within the hydraulically remote area. <br /> GRINNELL Tri-Seal Gaskets.A petro- to be calculated. If less than 5 sprin- NFPA 13 states,when fluid delivery Is <br /> leum-free silicone lubricant is to be klers are on a branchline,all sprinklers based on four(4) sprinklers, the test <br /> utilized on grooved coupling gaskets. on the appropriate branchlines are to shall simulate two sprinklers on each of <br /> When standard gaskets are employed, be calculated up to the required total. two branchlines.The Annex goes on to <br /> sta small annular "groove" is left- The SprinkFDT-Q Fluid Delivery the twe o remote thete brasprnchliersnes. <br /> shall. be from <br /> between the ends of the two pipes Calculation Program must be used the two branchlines. <br /> to be coupled. This annular gap can to assure water delivery within the Fluid Delivery(Operating)Time <br /> fill with water any time the system is prescribed maximum and minimum Safety Factor <br /> flooded,such as during hydrostatic or times,as well as to take pump start up There are three (3) options available <br /> water delivery time testing.It is virtually time into consideration.When running when performing the Fluid Delivery/ <br /> impossible to remove this water,which fluid delivery calculations, the calcu- Maximum Operating Time calculations. <br /> will then freeze when the freezer is lotions must include the path back to The option chosen will determine the <br /> placed into operation.The expansion the point of connection with the water required operating time safety factor. <br /> of the water as it freezes can damage supply source. This assures that the <br /> the gasket,and In severe cases even impact of inertia will be considered Option 1: Four (4) Sprinkler Test <br /> damage the coupling or even lead to within the underground supply piping. Manifold - When a 4-sprinkler test <br /> joint failure. manifold is piped from the remote 2 <br /> When establishing the differential trip <br /> branchlines in accordance with NFPA <br /> Where GRINNELL grooved type ratio on the SprinkFDT-Q, set the trip 13, the following procedure shall be <br /> couplings are being utilized,the Figure value to zero(0)in the device parameter utilized.Perform the 4-sprinkler calcu- <br /> 577 Rigid couplings must be utilized box,then select ENTER. lotions on the overhead system with no <br /> throughout the overhead system with Note:When running the SprinkFDT-Q specific "cushion" or "safety factor" <br /> the exception of flexible joints where calculations,a warning dialog box will required(All piping to test header must <br /> required by NFPA for strain relief. In appear stating "The dry pipe valve is be included/modeled in all calcula- <br /> this case,GRINNELL Figure 705 flexible set to deluge conditions". Select YES tiros).Atter confirming that the calcu- <br /> type couplings must be utilized. to continue. lated overhead sprinklers do not <br /> (10)Control Valves Also, when applying the fluid delivery exceed the maximum allowed operating <br /> The Main Control Valve(preaction and calculation program, the fixed trip time, run an additional calculation for <br /> L dry)and System Shut-Off Valve (pre- time to be entered for the Model QRS the 4-sprinkler test manifold by closing <br /> action only)must be supervised in the Electronic Accelerator is 4 seconds. the previous four(4)overhead normally open position. The use of In order to accuratelyredict water sprin- <br /> klers and opening the four (4) test <br /> Model BFV-N or Model JPL Butterfly p manifoldes sprour sprinklers <br /> The rs notisu time <br /> dalterrs time, the use of an accurate to these four n note oft he <br /> Valves are recommended.The BFV-N water supply curve isi critical for the overhead ee simnkl r (i.e.ma time rethe <br /> Valves are described in TFP15W, Progra DT-Q Fluid Delivery Calculation tha30 seconds). <br /> eresubet water <br /> TFP15/5,and TFP1520. Program. than 30 seconds).The resultant water <br /> (11)Red-E Cabinet Simulated Open Sprinklers for Fluid delivery time to these four sprinklers as <br /> The DV-5 Preaction Red-E Cabinet Delivery Calculations shown in the calculated results must <br /> (without air compressor)that can house In accordance with Tables A, B, or C, not be exceeded during the field test. <br /> Items 2 thru 6 is recommended. This both the maximum and the minimum Option 2:One(1)Sprinkler Inspectors <br /> component is described in TFP1400. water delivery time must be calculated. Test-When a single sprinkler inspec- <br /> The required number of sprinklers to tors test is installed, the following <br /> Design simulate "open" for determining fluid procedure shall be utilized. Perform <br /> delivery time is four(4).TFPP recom- the 4-sprinkler calculations on the <br /> Criteria mends that the four (4) sprinklers overhead system with a 5% "safety <br /> utilized, consist of the two (2)remote factor" required (All piping to test <br /> TYCO QUELL Preaction and Dry sprinklers each on the two(2)remote header must be included/modeled in all <br /> Systems are an Innovative approach branchlines within the hydraulic remote calculations).After confirming that the <br /> to addressing a high-challenge fire area.The sequence of operation of the calculated overhead sprinklers do not <br /> hazard that departs from previous four (4) sprinklers should be based exceed the maximum allowed operating <br /> control mode and suppression mode on the linear length of pipe from time with a 5% safety factor, run an <br /> approaches and instead employs a the sprinkler to the source. For the additional calculation for the 1-sprinkler <br /> sprinkler operational area sufficient to maximum delivery time calculations, test manifold by closing the previous <br /> surround and drown the fire. the first sprinkler operation is based four (4) overhead sprinklers and <br /> Except as modified below, all instal- on the longest linear length from the opening the single sprinkler inspec- <br /> source. For the minimum delivery time tors test connection. The resulting <br /> lation criteria provided in NFPA 13 calculation,the first sprinkler operation time to this single sprinkler inspec- <br /> applies. is based on the shortest linear length tors test connection is not subject to. <br /> Hydraulic Design and from the source, the maximum operating time of the <br /> Water Delivery Under certain system piping configure- overhead sprinklers he.may be greater <br /> The hydraulic design,maximum water tions,a group of four sprinklers other than 30 seconds).The resultant water <br /> . delivery time, and minimum water than the 4 sprinklers described above, delivery time to this single sprinkler <br /> [ delivery time must be in accordance can result in a longer delivery time. If inspectors test "sprinkler" as shown <br /> 4 with Table A,B,or C,as applicable.For this group of sprinklers is not within in the calculated results must not be <br /> exceeded during the field test. <br />
The URL can be used to link to this page
Your browser does not support the video tag.