CHAPTER 12 <br /> tor INTERIOR ENVIRONMENT <br /> SECTION 1201 located in the upper portion of the attic or rafter <br /> GENERAL space. Upper ventilators shall be located not more <br /> 1201.1 Scope. The provisions of this chapter shall govern than 3 feet (914 nun) below the ridge or highest <br /> ventilation, temperature control, lighting, yards and courts, point of the space,measured vertically,with the bal- <br /> sound transmission,room dimensions, surrounding materials once of the ventilation provided by eave or cornice ?' <br /> and mdentproofng associated with the interior spaces of vents. Where the location of wall or roof framing . <br /> buildings. members conflicts with the installation of upper �.'I; <br /> ventilators, installation more than 3 feet (914 min) I: <br /> below the ridge or highest point of the space shall be <br /> SECTION 1202 permitted. <br /> • <br /> DEFINITIONS 1203.2.1 Openings into attic. Exterior openings into the } <br /> 1202.1 General.The following tends are defined in Chapter 2: attic space of any building intended for human occupancy i <br /> SUNROOM. shall be protected to prevent the entry of birds, squirrels, ); <br /> rodents, snakes and other similar creatures. Opening • <br /> s for <br /> THERMAL ISOLATION. ventilation having a least dimension of not less than 7,s • <br /> inch(1.6 mm)and not more than 4,inch(6.4 mm)shall be <br /> permitted. Openings for ventilation having a least dimen- r <br /> SECTION 1203 sion larger than 44 inch (6.4 mm) shall be provided with <br /> VENTILATION corrosion-resistant wire cloth screening, hardware cloth, <br /> 1203.1 General. Buildings shall be provided with natural perforated vinyl or similar material with openings having a r' <br /> ventilation in accordance with Section International,or mechanical <br /> least dimension of not less than /,s inch(1.6 nun) and not • <br /> • <br /> ventilation in accordance with the Mechanical more than Y4 inch (6.4 mm). Where combustion air is <br /> �fe. obtained from an attic area,it shall be in accordance with 1i <br /> Chapter 7 of the International Mechanical Code. ., <br /> Where the air infiltration rate in a dwelling unit is less than <br /> 5 air changes per hour when tested with a blower door at a 1203.3 Unvented attic and unvented enclosed rafter O. <br /> pressure 0.2 inch w.e. (50 Pa) in accordance with Section assemblies. Unvented attics and unvented enclosed roof <br /> 402.4.1.2 of the International Energy Conservation Code— framing assemblies created by ceilings applied directly to the 1' <br /> Residential Provisions, the dwelling unit shall be ventilated underside of the roof framing members/rafters and the strut- , <br /> by mechanical means in accordance with Section 403 of the tural roof sheathing at the top of the roof framing members <br /> International Mechanical Code. Ambulatory care facilitiesI <br /> shall be permitted where all the following conditions are met: <br /> and Group 1-2 occupancies shall be ventilated by mechanical 1. The unvented attic space is completely within the <br /> means in accordance with Section 407 of the International building thermal envelope. <br /> 2. No interior Class I vapor retarders are installed on the <br /> ,;� <br /> Mechanical Code. <br /> 1203.2 Ventilation required. Enclosed attics and enclosed ceiling side(attic floor) of the unvented attic assembly <br /> rafter spaces formed where ceilings are applied directly to the or on the ceiling side of the unvented enclosed roof =$' <br /> underside of roof framing members shall have cross ventila- framing assembly. <br /> Hon for each separate space by ventilation openings protected 3. Where wood shingles or shakes are used,a minimum '/4- <br /> against the entrance of rain and snow.Blocking and bridging inch(6.4 mairspace in) vented separates the shingles or <br /> shall be arranged so as not to interfere with the movement of shakes and the roofing underlayment above the shoo- <br /> air.An airspace of not less than 1 inch(25 mm) shall be pro- tural sheathing. <br /> vided between the insulation and the roof sheathing. The net <br /> free ventilating area shall be not less than Viso of the area of 4. In Climate Zones 5, 6, 7 and 8, any air-impermeable <br /> the space ventilated. Ventilators shall be installed in actorIL <br /> insulation shall be a Class II vapor retarder or shall <br /> dance with manufacturer's installation instructions. have a Class III vapor retarder coating or covering in <br /> Exception: The net free cross-ventilation area shall be direct contact with the underside of the insulation. <br /> permitted to be reduced to '/jw provided both of the fol- 5. Insulation shall be located in accordance with the fol- <br /> lowing conditions are met lowing: '} <br /> 1. In Climate Zones 6, 7 and 8, a Class I or II vapor 5.1. Item 5.1.1, 5.1.2, 5.1.3 or 5.1.4 shall be met, <br /> retarder is installed on the warm-in-winter side of depending on the air permeability of the insula- <br /> the ceiling. tion directly under the structural roof sheathing. <br /> 2. At feast 40 percent and not more than 50 percent of 5.1.1. Where only air-impermeable insula- <br /> the required venting area is provided by ventilators tion is provided, it shall be applied <br /> 2015 INTERNATIONAL BUILDING CODE° 311 <br />