My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13007133
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
15-XXXXXX
>
13007133
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:00:20 PM
Creation date
8/6/2025 2:07:51 PM
Metadata
Fields
Template:
Permits
Permit Address
111 LOCUST ST W
Permit City
Stayton
Permit Number
555-15-006140-STR
Parcel Number
091W10BD07700
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
I <br /> I <br /> INTERIOR ENVIRONMENT <br /> tirI in direct contact with the underside of the structuralat the perimeter of each individual sheet interior <br /> roof sheathing. <br /> 5.1.2. Where air-permeable insulation is <br /> surface to form a continuous layer. <br /> Exceptions: <br /> provided inside the building thermal 1. Section 1203.3 does not apply to special use stmc- <br /> envelope, it shall be installed in tares or enclosures such as swimming pool enclo- <br /> accordance with Item 5.1. In addi- sores, data processing centers, hospitals or art <br /> tion to the air-permeable insulation galleries. <br /> installed directly below the struc- <br /> tural sheathing, rigid board or sheet 2. Section 1203.3 does not apply to enclosures in Cli_ <br /> ' insulation shall be installed directly mate Zones 5 through 8 that are humidified beyond <br /> • <br /> • <br /> above the structural roof sheathing 35 percent during the three coldest months. <br /> in accordance with the R values in 1203.4 Under-floor ventilation. The space between the bot- <br /> Table 1203.3 for condensation con- torn of the floor joists and the earth under any building except <br /> trol. spaces occupied by basements or cellars shall be provided <br /> with ventilation openings through foundation walls or exte- <br /> 5.1.3. Where both air-impermeable and rior walls. Such openings shall beplaced so as to provide <br /> I air-permeable insulation are pro- <br /> sided, the air-impermeable insula- cross ventilation of the under-floor space- <br /> tion shall be applied in direct contact 1203.4.1 Openings for under-floor ventilation. The net <br /> with the underside of the structural area of ventilation openings shall be not less than 1 square <br /> roof sheathing in accordance with foot for each 150 square feet(0.67 m2 for each 100 m1)of <br /> Item 5.1.1 and shall be in actor- crawl-space area. Ventilation openings shall be covered <br /> dance with the R values in Table for their height and width with any of the following mate- <br /> ," 1203.3 for condensation control. rials, provided that the least dimension of the covering <br /> The air-permeable insulation shall shall be not greater than I/a inch(6.4 mm): �; <br /> be installed directly under the air- 1. Perforated sheet metal plates not less than 0.070 <br /> impermeable insulation. inch(1.8 mat)thick. <br /> 5.1.4.• Alternatively, sufficient rigid board 2. Expanded sheet metal plates not less than 0.047 inch <br /> or sheet insulation shall be installed (1.2 mm)thick <br /> directly above the structural roof <br /> sheathing to maintain the monthly 3. Cast-iron grilles or gratings. <br /> average temperature of the under- 4. Extruded load-bearing vents. <br /> E. side of the structural roof sheathing <br /> above 45°F (7°C). For calculation 5. Hardware cloth of 0.035-inch (0.89 mm) wire or <br /> • <br /> t purposes, an interior air temperature <br /> heavier. <br /> of 68°F (20°C) is assumed and the 6. Corrosion-resistant wire mesh,with the least dimen- <br /> exterior air temperature is assumed sion not greater than'/s inch(3.2 rum). <br /> to be the monthly average outside air 1203.4.2 Exceptions. The following are exceptions to <br /> • temperature of the three coldest Sections 1203.4 and 1203.4.1: <br /> • months. <br /> • 1. Where warranted by climatic conditions,ventilation <br /> 5.2.Where preformed insulation board is used as the openings to the outdoors are not required if ventila- <br /> air-permeable insulation layer,it shall be sealed Lion openings to the interior are provided. <br /> • <br /> • <br /> I TABLE 1203.3 <br /> INSULATION FOR CONDENSATION CONTROL <br /> CLIMATE ZONE MINIMUM R-VALUE OF AIR-IMPERMEABLE INSULATION' <br /> 28 and 3B tile roof only 0(none required) <br /> I,2A,28,3A,3B,3C R-5 <br /> 4C R-10 <br /> 4A,48 R-15 <br /> ' 5 R-20 <br /> 6 R-25 <br /> 7 R-30 = <br /> 411/ $ R-35 <br /> a. Contributes to, but does not supersede, thermal resistance requirements for attic and roof assemblies in Section C40221 of the International Energy <br /> Conservation Code. <br /> 312 2015 INTERNATIONAL BUILDING CODE" <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.