Laserfiche WebLink
Application Instructions For Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS DS300 <br /> d. Spray/Back-rolling Application <br /> 1)Apply Dryvit Grid Tape as described in Section IV.E.1 above. Mix the material as described in <br /> Section I and using a stainless steel trowel or spatula, apply a layer of Backstop NT-Texture over <br /> the grid tape and spot all fastener heads. Allow to dry for a minimum of 2 hours or until dry to the <br /> touch. <br /> 2) Because of the absorption characteristics, plywood substrates may require a second pass to fill any <br /> voids at the sheathing joints. After the first pass has dried,check the joints and spot any voids that <br /> may be present with additional Backstop NT-Texture material and allow to dry. <br /> 3) Using a hand held hopper gun or other suitable texture spray equipment, spray a layer of Backstop <br /> NT-Texture onto the wall surface. Using a coarse, open-cell foam roller cover with a 3/8 in <br /> (9.5 mm)foam nap(FoamPRO#58 roller), roll the material to create a smooth continuous film. <br /> NOTE: If the roller pulls material back out of the sheathing joints, it indicates that the joint <br /> material is not sufficiently dry. <br /> 4)While Backstop NT-Texture is still wet, using a trowel or spatula,smooth out the Backstop NT- <br /> Texture around all window and door perimeters and other areas that will later receive Dryvit <br /> Flashing Tape—Figure 3. <br /> 5)Backstop NT-Texture material should be applied in a uniform, continuous film at the recommended <br /> coverage rate. NOTE: Substrates with a surface texture or high porosity will require <br /> additional material. <br /> 3. Backstop NT-Smooth Application <br /> a. General: Dryvit Backstop NT-Smooth can be applied using a roller or sprayed and back-rolled over the <br /> acceptable sheathing substrates. NOTE:OSB sheathing requires that joints and fasteners be <br /> treated with Backstop NT-Texture.A minimum of two(2)coats of Backstop NT-Smooth or <br /> Backstop NT-Spray are required for the field of the wall. Backstop NT-Texture is not <br /> recommended for application in the field of the board. <br /> b. Sheathing Substrates:All fastener heads shall be spotted and joints treated with Backstop NT-Texture <br /> and Dryvit Grid Tape in accordance with Section IV.E.1 prior to Backstop NT-Smooth application. <br /> c. Roller Application <br /> 1) Using the appropriate nap roller(see Usage Application Chart), apply the Backstop NT- Smooth <br /> over the entire wall surface, including previously treated joints. NOTE: If the roller pulls material <br /> back out of the sheathing joints, it indicates that the joint material is not sufficiently dry. <br /> 2) Backstop NT-Smooth material should be applied in a uniform,continuous film at the recommended <br /> coverage rate—Figure 4. NOTE:Sheathing substrates with a surface texture or high porosity <br /> will require additional material. <br /> Backstop NT- <br /> Texture <br /> topNT- <br /> Smoo <br /> Smooth <br /> Figure 4 <br /> d. Spray/Back-rolling Application <br /> 1) Backstop NT-Smooth may be applied to the wall using a hopper gun or texture spray equipment <br /> and back-rolled using the appropriate nap roller(see Usage Application Chart). <br /> 2)Allow the Backstop NT-Smooth to completely dry, check the wall to ensure that the Backstop NT- <br /> Smooth is continuous and touch up any visible voids with additional Backstop NT-Smooth material. <br /> e.Allow the Backstop NT-Smooth to completely dry prior to installation of the specified cladding. <br /> 8 <br />