My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13007268
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
16-XXXXXX
>
13007268
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:00:18 PM
Creation date
8/6/2025 2:54:29 PM
Metadata
Fields
Template:
Permits
Permit Address
6150 KEIZER STATION BLVD NE
Permit City
Keizer
Permit Number
555-16-003812-STR
Parcel Number
063W36A 04200
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Application Instructions For Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS DS300 <br /> 4. Backstop NT- Spray Application <br /> a. General: Dryvit Backstop NT-Spray can be applied using appropriate spray equipment over the <br /> acceptable sheathing substrates. <br /> 1)Airless spray equipment must be capable of providing minimum 3000 psi and minimum material flow <br /> of 1 gallon per minute with a minimum .021 spray tip. <br /> NOTE: OSB sheathing requires that joints and fasteners be treated with Backstop NT-Texture. <br /> A minimum of two(2)coats of Backstop NT-Smooth or Spray are required for the field of the <br /> wall. Backstop NT-Texture is not recommended for application in the field of the board. <br /> b. Sheathing Substrates: All fastener heads shall be spotted, and joints treated with Backstop NT- <br /> Texture and Dryvit Grid Tape in accordance with Section IV.E.1 prior to Backstop NT-Spray <br /> application. <br /> 1) Backstop NT-Spray material should be applied in a uniform, continuous film at the recommended <br /> coverage rate free of voids and pinholes-Figure 5. NOTE: Sheathing substrates with a surface <br /> texture or high porosity will require additional material. <br /> Backstop NT- <br /> TeNure <br /> 8 ( • <br /> I i/ 4 Backstop NT- <br /> Spray <br /> Figure 5 <br /> c. Concrete/Masonry Substrates <br /> 1) Backstop NT-Spray may be applied to the wall using appropriate airless spray equipment and <br /> back-rolled using the appropriate nap roller(see Usage Application Chart). <br /> 2)Allow the Backstop NT-Spray to completely dry, check the wall to ensure that the Backstop NT- <br /> Spray is continuous and touch up any visible voids with additional material. <br /> d.Allow the Backstop NT-Spray to completely dry prior to installation of the specified cladding. <br /> V. Detailing at Transitions <br /> A. The Backstop NT membrane must be tied into all openings and penetrations to achieve continuity of the air <br /> barrier and it must be integrated with flashing material to eliminate water penetration. <br /> 1. Integration with flashing, openings and terminations <br /> a. Dryvit AquaFlash <br /> 1) May be applied directly over clean galvanized, painted metal,or PVC flashing. <br /> 2)Clean the surface of the flashing to ensure it is free of dirt, dust, oil, or other contaminants that may <br /> interfere with adhesion. Note: PVC products should be lightly abraded to break the surface skin and <br /> provide tooth for the coating. <br /> 3) Refer to Dryvit AquaFlash Application Instructions DS196 for application and sequencing. <br /> b. Dryvit Flashing Tape <br /> 1) Refer to Dryvit Flashing Tape Data Sheet DS450. <br /> 411,1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.