My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13010122
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
19-XXXXXX
>
13010122
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:00:20 PM
Creation date
8/6/2025 4:33:55 PM
Metadata
Fields
Template:
Permits
Permit Address
595 CHEMAWA RD N
Permit City
Keizer
Permit Number
555-19-001282-STR
Parcel Number
073W03AA03200
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
tgCQ® Worldwide Tyco-fire.com <br /> Contacts <br /> Model WS Specific Application Window Sprinklers <br /> Horizontal and Pendent Vertical Sidewall <br /> 5.6 K factor <br /> General with Section 104 of the IBC("Alternate <br /> Materials,Design and Methods of Con- <br /> Description 2i \ <br /> sttuation and Equipment"). Also, the .,! 4p <br /> Model WS Window Sprinklers can be i I/ <br /> The TYCO Model WS Specific Appli- used as an open sprinkler for"Outside r7-,'+" <br /> cation Window Sprinklers are fast Sprinkler Protection against Exposure 1,s ,r <br /> response,glass bulb-type spray spnn- Fire",using the design requirements of t is {:^4 1 <br /> klers available in Horizontal Sidewall NFPA. VP' ai, f • - <br /> and Pendent Vertical Sidewall models. As with any specific application sprin v, 1,--r .y <br /> These sprinklers are the first to be kler, the installation instructions - <br /> specifically Listed to provide corn- included in this data sheet must be pre- <br /> pieta wetting and coverage for heat cisely followed. If there are additional <br /> strengthened, tempered, or ceramic local or jurisdictional installation stan- <br /> glass windows using closed sprin- dards/codes for window sprinklers on <br /> klers. As part of the testing the gas glazed window systems,this document <br /> flow required to achieve the time/ does not relieve the designer/installer <br /> temperature relationship specified in from these requirements.Consult your <br /> ASTM E119 was established in a test local jurisdiction to verify if or when <br /> furnace without sprinkler protection.A these additional guidelines must be ,I <br /> Cowindow assembly protected with the followed. <br /> TYCO Model WS Window Sprinklers <br /> was then installed in the test furnace, NOTICE <br /> and the same gas flow conditions were TYCO Model WS Specific Application War <br /> •aPh <br /> maintained for a two-hour test period. Window Sprinklers described herein r. SIpE <br /> No cracking or visible damage to the must be installed and maintained in Wait <br /> window was permitted during the test compliance with this document, as <br /> period, even when a hose stream was well as with the applicable standards <br /> directed at the window. recognized by the approval agency, in <br /> The success of the Model WS Window addition to the standards of any author- <br /> Sprinklers is based on their fast flies having jurisdiction.Failure to do so <br /> response thermal sensitivity and on may impair the performance of these <br /> their specially designed deflectors that devices. <br /> ensure that the spray pattern wets the The owner is responsible for main- <br /> entire surface of the window. taining their fire protection system <br /> Based on successful testing, the and devices in proper operating con- <br /> Model WS Window Sprinklers can be dition. Contact the installing contrac- <br /> used as interior protection of windows for or product manufacturer with any <br /> or glazing in a sprinklered building or questions. <br /> non-sprinklered building in accordance Sprinkler <br /> IMPORTANT Identification <br /> Refer to Technical Data Sheet <br /> TFP2300 for warnings pertaining to Number (SIN) <br /> regulatory and health information. <br /> Always refer to Technical Data TY3388-Horizontal Sidewall <br /> Sheet TFP700 for the INSTALLER TY3488-Pendent Vertical Sidewall <br /> WARNING" that provides cautions TY3388 is a re-designation for C3388 <br /> with respect to handling and instal- TY3488 is a re-designation for C3488 <br /> lation of sprinkler systems and com- <br /> ponents. Improper handling and <br /> Iiir installation can permanently damage <br /> a sprinkler system or its compo- <br /> nents and cause the sprinkler to fail <br /> to operate in a fire situation or cause <br /> it to operate prematurely. <br /> Page 1 of 8 AUGUST 2018 TFP62O <br />
The URL can be used to link to this page
Your browser does not support the video tag.