Laserfiche WebLink
TFP620 <br /> Page 2 of 8 <br /> Technical Components: <br /> - Frame <br /> Data 2 - Button 4eNr� N *Temperature <br /> 3 - Sealing , __Y-NY' rating is <br /> Approvals Assembly %%�����— indicated on <br /> UL and C-UL Listed 4 - Bulb n. ,.�.\ Deflector. <br /> NYC under MEA 289-04-E 5 - Compression <br /> Approvals only apply to the service Screw <br /> conditions indicated in the Design Cri- 6 - Deflector* <br /> teria section. 1 2 3 4 5 6* <br /> Additional Recognition CROSS SECTION PLAN <br /> ICC Evaluation Service(ESR-2397) <br /> Ontario Building Code <br /> Pipe Thread Connection THREAD SPRINKLER INDICATED TOP <br /> 1/2 in.NPT RELIEF FRAME ARMS OF SPRINKLER <br /> DEFLECTOR <br /> Discharge Coefficient <br /> K=5.6 GPM/psia(80,6 LPM/bare) 1/2° <br /> Temperature Ratings NPT <br /> 155°F(68°C) 13/16" <br /> 200°F(93°C) II( ll (20,6 mm) <br /> CENTERLINE sisal <br /> Finish OF SPRINKLER is f <br /> Natural Brass WATERWAY II�IIIII 1-5/2°DIA. <br /> Signal White(RAI-9003)Polyester IX1111 (41,3 mm) <br /> Jet Chrome klaPolyestar <br /> Chrome (RAL9005) <br /> AL <br /> ted <br /> Physical Characteristics 7/16"(11,1 mm) WRENCH <br /> Frame Brass NOMINAL MAKE-INy FLATS ORIENT <br /> Button Bronze/Copper DEFLECTOR <br /> Sealing Assembly..Beryllium Nickel w/TEFLON 2-1/8" TOWARDS <br /> Bulb Glass(3 mm dia.) (54,0 MM)—_' WINDOW <br /> Compression Screw. Brass <br /> deflector Brassl&onze <br /> 44 <br /> Operation SIDE ION <br /> FIGURE <br /> The glass bulb contains a fluid that MODEL WS WINDOW SPRINKLER <br /> expands when exposed to heat.When HORIZONTAL SIDEWALL <br /> the rated temperature is reached, the <br /> fluid expands sufficiently to shatter the Components: <br /> glass bulb, allowing the sprinkler to <br /> activate and water to flow. 1 - Frame 4 - Bulb *Temperature <br /> 2 - Button 5 - Compression rating is indicated <br /> 3 - Sealing Screw on Deflector. 1/2" 7/16"(11,1 mm) <br /> Assembly 6 - Deflector* NPT NOMINALMAKE-IN <br /> 1 <br /> WRENCH =� <br /> 2 FLATS <br /> \� <br /> 3 f C FLOW ARROW SPRINKLER n7 2-1/8° <br /> Al ` " (INDICATED ON FRAME �� (54,0 mm) <br /> ' I DEFLECTOR) ARMS <br /> 4 TOWARDS <br /> 5 i - WINDOW <br /> ��� f <br /> 1i <br /> _` <br /> CENTERLINE TOP OF <br /> OF SPRINKLER — 6* SPRINKLER 1-1/32" <br /> WATERWAY DEFLECTOR y (26,2 mm) '~ <br /> 5/8" 2-1/16° <br /> (15,9 mm) (52,4 mm) <br /> CROSS SECTION TOWARDS WINDOW ELEVATION 1 <br /> FIGURE 2 V <br /> MODEL WS WINDOW SPRINKLER <br /> PENDENT VERTICAL SIDEWALL <br />