Laserfiche WebLink
September 29, 1993 <br /> <br />SITE NU~ER: 93-~17~ <br /> <br /> Your site has been found suitable for a SAND FILTER PLUS FULL CAPPING <br />FILL ALTERNATIVE SEWAGE DISPOSAL SYSTEM. The following construction specifica- <br />tions shall apply to the installation Of your septic system. <br /> <br /> 1. The septic =ask shall have a minimum liquid capacity of 1000 <br /> gallons. <br /> <br /> 2. The projected daily sewage flow for thi~ pro~e¢~ is calculated at <br /> 45O qallQns Der day. Based o~ soil conditions observed on this <br /> site, the di~lDosal field will be sized at .~0 lineal feet ..~r 150 <br /> ~ens of projected daily sewage flow. A minimsm of 150 lineal <br /> fee~ of disposal field will be required for your proposed develop- <br /> ment. The disposal trenches a~e constructed two (2) feet wide and <br /> on minimum ten (~0) foot centers and with no line exceeding <br /> feet in length. The trenches and perforated pipe ar~ installed <br /> level (i1") and contoured to follow the natural ground surface- <br /> <br /> The disposal field shall be Constructed with equ~l distributio~ <br /> with a minimum trench depth of 12 inches and a maximum trench <br /> depth of 12 ino.hes. The capping ~ill material must be inspected <br /> and approved prior to placement. ~he fill shall be of the same <br /> textural claes, or one class finer, than the native topsoil. The <br /> disposal field area must be scarified to destroy any vegetative <br /> mat on the surface, Fill material shall be evenly graded to a <br /> final depth of sixteen (16) inshes eve= ~he grav~l- cappi~q Fill <br /> systems .~Ball be. const~cted between June 1 a~ .~c~ob~ 1 <br /> du~im~ such tia~e$ when our .s~ff finds soi~ moisture <br /> <br />Th~ ~i~ m~st b~ p~otected from ~affic, livestock, far, lng or <br />o~her damaging activities. <br /> <br /> An effluent lift pump may be necessary fo construct the disposal field <br />in the approved area and at the correct depth. <br /> <br /> This approval ia site sl~eeific to the ar~a tested and the septic system <br />must be located in the immediate area of the test pits unless otherwise authO- <br />rized by this office. A sew sit~ evaluation may be required if the system is <br />proposed for a different area on the property. <br /> <br />SPECIAL CONDITIONS~ <br /> Plans for the Sand filter/capping fill repair should be submitted for <br /> plan review as soon as possible as the permit cannot be issued until the <br /> plans, are approved. The existing septic tank must be pumped and properly <br /> abandoned. Observe all normal setback/separation distances. Refer to the <br /> enclosed setback list. <br /> <br />UNTIL A vALT~D PERMIT ~U%,S ISE~I~,,,,I,,SSUED BY THIS OFFICE. <br /> <br /> <br />