10. <br /> <br />11. <br /> <br />12. <br /> <br />13. <br /> <br />2. An uncoated No. 4 reinforcing bar stubbed up at least 12 inches above the floor plate line and <br />tightly attached to file rehfforcing bar located in the footing. The spliced lap of the stubbed up bar <br />to the footi~ ~ shall be a mlnlmllm of 12 inches. <br /> <br />ENCLOSED ACCESSIBLE SPACE under stairs shnH have walls ~ soffits protected on the enclosed side <br />wifil 1/2 inch gypsum boasd. <br /> <br />STAIRWAYS sh~ll not be less than 36 inches in clear width at all points between the handrail height and the <br />required minimllm headroom of 6 feet 8 inches. Minimom width from the haudrall down is 32 inches wifil <br />one h~ndrall, 28 inches with two. T~e minlrmun required stair freud width is 9 inches. The maximum stair <br />rise is 8 {ne_ht~. When risers are closed, all ueads less th~n 10 inches shall have a u~form nesing between <br />3/4 inches and 1 1/4 inches. The greatest riser haigh~fflreed depth shall not exceed the smallest by more than <br />3/8 inch. <br /> <br />HANDRAILS having a minimum and maximum height of 30 inches and 38 inches, respecl~vely, shall be <br />provided on at least one side of stairways of more than three risers. All reqllired handraJis sh~l! be <br />continuous thc full leagth of the stairs. Ends shall be remroed or sh~l terminR~e in newel posts or safety <br />termin~lS. Exception: HandraiLs may be interrupted by a newel post at a turn, and file use of a volute turnout <br />or starting easing shall he allowed over the lowest trcad. <br /> <br />THE HANDGRIP PORTION of handrails shall not be less th~n 1 1/4 inches or more than 2 5/8 inches in <br />cross-sectional dimension, or the shape shall provide an equivalent gripping surface. The handgrip pol~ion <br />shall have a smooth surface and edges shall have a minimum radin$ of lis inch. <br /> <br />OUARDRAILS. Porches, balconies or raised floor surfaces located more than 30 in. above the floor or <br />grade shall have guasdsails not less than 36 inches in height. Required guardrall shall have intermediate rails <br />or ornamental closu~s which will not allow passage of an object 6 in. or more in diameter. Horizontal <br />spacing between the venieal members in required guardraiis shall be a maxi~rmm of 4 inches at file nearest <br />point between the members. <br /> <br />GUARDRAIL ON STAIRS. Open sides of stairs with a total rise of more thsn 30 inches above file floor or <br />grade below.shall have guardrails not less th~n 34 inches in height measured vertically from the nosing of <br />the tseads. Guardrali shall have intermediate rails or ornamental closures which will not allow passage of an <br />object 6 in. or more in diRmeter. Horizontal spacing between file vertical members in required guardrails <br />shall be a maximum of 4 inches at file nearest point between the members. <br /> <br />EVERY SLEEPING ROOM shall have at least one open,abM window or exterior door approved for <br />emergency egress or rescue. The window sill height shall not he more than 44 inches above thc floor. The <br />minimllm net clear openln~ is 5.7 square feet. Thc mlnin~lm net clear openin..~ height shall he 22 inches. <br />Thc mlnlrmlm net clear openln~ width shall he 20 inches. Exceplion: Grade floor windows may have a <br />minin'mnl net ~lear Openln~ of $ square feet. <br /> <br />THE GARAGE shall be separated from the dwellin~ and its a~ic area by means of 1/2-inch gypsum board <br />apphed to the garage side of the wall. Where the separalion is a floor-ceiling assembly, the strncUire <br />supporling the soparafion shall he protected by 1/2-ineh gypsum board or equivalent. The door between file <br />garage and residence shall be equipped with solid wood doors not less flaan 1 3/8 inches in thiclmess or 20- <br />minute fire rated, or equivalent. <br /> <br />SMOKE DETECTORS sbsll be installed in each sleeping mom, outside of each separate sleeping area in the <br />immediate vicinity of the bedrooms and on each additional stovJ of ~he dwellin~o includin~ basemaBts. All <br />detectors shall be interconnected such that lhe actoation of one alarm will actuate all the alarms in the <br />individual unit and sl~{{ provide an alarm which will be audible in all sleeping areas. Smoke detectors shall <br />he 110 volt with hattey hock-up.' <br /> <br />SMOKE DETECTOR/POWER. Required smoke detectors shall receive their primary power from tbe <br />building wiring when such wiring is servcd from a commercial source, and when prlrr~ry power is inter- <br />rupted, shall receivc power from a battery. Smoke detectors may he battery operated when installed in <br />buildings without commercial power. <br /> <br />2-Stov~ Review 2 <br /> <br /> <br />