Laserfiche WebLink
14. <br /> <br />15. <br /> <br />16. <br /> <br />17. <br /> <br />FIRESTOPPING shall be provided in ~he following locations: <br /> 1) In concealed spaces of stud walls, including furred spaces not to exceed 10 feet horizontally, <br /> and at the ceiling and floor level. <br /> 2) At all intcrconn~ions between concealed vertical and horizontal spaces such as occur at soffits, <br /> drop or cove ceilings, etc. <br /> 3) In concealed spaces between stair stringers at the top and bottom of the nm and wall cavities in <br /> line with the stringers; <br /> 4) At openings atotmd vents, pipes, ducts, chimneys and fireplaces at ceiling and floor level, with <br /> noncombustible materials. <br /> <br />HEATING AND COOLING appliances located in a garage shall be protected from impact by automobiles. <br />Appliances that generate a glow, spark or flame capable of igniting gasoline vapOrs located in a garage ,hall <br />be installed with burners, burner ignition devices or heating elements and switches at least 18 inches above <br />the floor level. <br /> <br />WATER HEATle~C5 shall be anchored or strapped to the buiJdlng to resist horizontal displacement due to <br />earfflqlla~ motion. <br /> <br />TRUSS DESIGN. Roof trusses are required to be designed by au Oregon registered Engineer or Architect. <br />For Umsses mamffactored by an approved fabrication plant, have the design and layout drawings available at <br />the construction site for the framing inspection. All job site cutting or modification of the roof u'usses shall <br />be clearly shown in the engin~r's design calculations and drawings. <br /> <br />"APPROVED" only when this sheet is attached to plans. <br /> <br />2-Story Review 3 <br /> <br /> <br />