My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1513704
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
98-XXXXX
>
BUILD - 1513704
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2010 11:45:48 AM
Creation date
11/16/2004 12:29:57 PM
Metadata
Fields
Template:
Permits
Permit Address
7878 SHERMAN RD SE
Permit City
Aumsville
Permit Number
555-98-05132
Parcel Number
081W29D 03402
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 2 <br /> <br />and structural changes made on site shall comply with <br />Oregon Revised Statute Chapter 455.040 and the 1997 <br />edition of the One and Two Family Dwelling Specialty <br />Code. <br /> <br />5. FOUNDATION/FOOTING LOADING. The foundation and its <br />structural elements shall be capable of accommodating all <br />superimposed live, dead and other loads according to <br />Section 301 and all lateral loads in accordance with the <br />provisions of the Code. Fills which support footings and <br />foundations shall be designed, installed and tested in <br />accordance with accepted engineering practice. [Sec. <br />401.2] <br /> <br />6. FOUNDATION SIZE. Footing and Foundation size minimum <br />requirements: <br /> Floors supported Footing size Stem <br /> Wall Thickness <br /> 1 6" x 12" 6" <br /> [Table 403.2] <br /> <br />7. GROUNDING ELECTRODES. When concrete reinforcing bars <br />are installed in concrete footings, the following <br />requirements shall be met to provide for a grounding <br />electrode system: <br /> 1. Uncoated No. 4 reinforcing bar installed not <br /> less than 20 feet in length encased with a minimum <br /> of 2 inches of concrete. <br /> 2. An uncoated No. 4 reinforcing bar stubbed up at <br /> least 12 inches above the floor plate line and <br /> tightly attached to the reinforcing bar located in <br /> the footing. The spliced lap of the stubbed up bar <br /> to the footing bar shall be a minimum of 12 inches. <br /> (See Section 4108.1.2.) [Sec. 403.4] <br /> <br />8. ANCHOR BOLTS. Foundation plates shall be bolted to <br />the foundation with a minimum ~ inch diameter by 10 inch <br />anchor bolts embedded at least 7 inches into concrete or <br />reinforced masonry and spaced not more than 6 feet apart <br />with a minimum of 2 bolts per piece with one bolt within <br />12 inches of the end of each piece. [Fig. 403.1a] <br /> <br />9. UNDERFLOOR VENTILATION. Provide at least 1 square <br />foot of underfloor ventilation for each 1500 square feet <br />of crawl space area. The openings shall be covered with <br />a corrosion resistant wire mesh. At least one such open- <br />ing shall be provided within 3 feet of each corner of the <br />building. Vents may be omitted on one side. Sec. 409.1] <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.