Laserfiche WebLink
DATE/TIME <br />TYPE <br /> <br /> SITE EVALUATION APPROVAL <br /> ', 05/20/98 16:02 APPROVAL NO : 98-03188 <br /> : SE STATUS : APPROVED <br /> APPROVED : 05/20/1998 <br /> PAGE 3 <br /> placement or any similar activities may also damage the soil <br /> in the area and adversely af:fect the septic system approval. <br /> The areas of the initial septic system and the future repair <br /> system must both be protected. <br />4. SAND FILTER systems are installed in soils where a layer <br /> that limits the effective soil depth, or a water table is <br /> present in the soil profile at a depth much shallower than <br /> allowed for a standard system. The sand filter unit <br /> pre-treats the septic tank effluent before it is discharged <br /> into the ground. The drainfield following the sand filter <br /> is installed at a very shallow depth and generally includes <br /> a capping fill drainfield. See the attached "Sand Filter <br /> System Requirements for Plans". Two sets of plans for the <br /> system must be submitted at the time of application for the <br /> installation permit. <br />5. A CAPPING FILL DRAINFIELD IS REQUIRED in conjunction with <br /> the septic system approval. See the attached "CAPPING FILL" <br /> information sheet for instructions. <br />6. CAPPING FILL systems are installed in soils where a layer <br /> that limits the effective soild depth or a water table is <br /> present in the soil profile at a depth shallower than <br /> allowed for a standard system. The drainfield is installed a <br /> at a very shallow depth and fill is placed over the field to <br /> provide the earth cover over the system, CAPPING FILL <br /> SYSTEMS MAY ONLY BE INSTALLED FROM JUNE 1 AND OCTOBER 1 or <br /> during such times when Building Inspection staff finds soil <br /> moisture conditions acceptable. See the attached "CAPPING <br /> FILL" information sheet for instructions. Fill material must <br /> be evenly graded over the drainfield and crowned at the <br /> center to shed rainfall. <br />7. THIS SYSTEM MUST BE INSPECTED AND APPROVED PRIOR TO BACKFILL <br /> When work is complete and ready for inspection, call our <br /> Automated Inspection Request line ,a.t 373-4427 to request an <br /> inspection. Enter the number "801 for a PRE-COVER inspec- <br /> tion. You may leave a message for the inspector if desired. <br /> Be sure the System Record form with the As-Built drawing is <br /> on the job or in our office when the inspection is requested <br /> An inspection should be completed within seven (7) days. <br /> <br /> <br />