Laserfiche WebLink
MANUFACTURED DWELLING PERMIT <br />DATE/TIME : 02/19/99 16:19 PERMIT NO <br />TYPE : New Manufactured Dwelling STATUS <br />UGB: SITE: FD ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />98-08084 <br />ISSUED <br />03/I9/1999 <br />09/15/1999 <br />2 <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SE-FBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br />This is a plan review covering the installation of the manufactured dwelling and is <br />to be Used for single family dwelling purposes only. This review does not include <br />any review of accessory structures, <br /> <br />Separate permits are required for accessory structures, including garages and <br />carports, electrical service, water lines, sewer lines, and septic systems. <br /> <br />The approved site plan shall be posted in a visible and readily accessible <br />location prior to the inspection request. The manufactured dwelling is to be <br />installed per the 1997 Oregon Manufactured Dwelling Standards, <br /> <br />The permit fee for this manufactured dwelling covers a maximum of three inspections. <br />(1) STAND inspection, prior to the installation of the manufactured dwelling: <br />(2) INSTALLATION inspection (Footings/Setbacks/Blocking and Connections): and <br />(3) FINAL inspection. All blocking, installation of temporary or permanent <br />stairs and plumbing, electrical, and mechanical conections are required prior <br />to an inspection requst. <br /> <br />A REINSPECTION FEE OF $60.00 shall be assessed for each inspection beyond the <br />permitted three inspections or (i) when the permit card or the approved site plan <br />is not posted on the job site: (2) for failure to provide access on the date for <br />which the inspection is requested; (3) when the work for which an inspection is <br />requested is not complete. (4) when the manufactured dwelling is not installed <br />per 1997 Manufactured Dwelling Standards: (5) for failing to attach an installer's <br />certification tag. or (6) when required corrections are not made, No inspections <br />will be performed until the reinspection fee has been paid at our office. <br /> <br />U)HER CUM~IENIS AND CUNDiIlUNS <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> A1-FENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2, THIS PLAN REVIEW WAS COMPLETED BY SF ON 9/18/1998 <br />3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br />4. Site grading and drainage shall provide grades which slope <br /> downward away from manufactured dwelling stands, foundation <br /> footings, concrete slabs, patios, walls, skirting, and <br /> foundations at a MINIMUM GRADE OF 1/2 INCH PER FOOT FOR 6 <br /> FEET horizontally. (Section 202(c) 1996 Oregon Manufactured <br /> Dwelling Code Standards). <br />5. Provide at least I square foot of underfloor ventilation <br /> for each 150 square feet of crawl space area, The openings <br /> shall be covered with a corrosion resistant wire mash. At <br /> least one such opening shall be provided within 3 feet of <br /> each corner of the building, (R-211,1) <br />6. Provi~ an access crawl hole to the underfloor space. The <br /> minimum size opening required is 18 inches by 24 inches. <br /> (R-211.2) <br />7. Stairways shall not be less than 2 feet in clear width and <br /> the headroom shall not be less than 6 feet 8 inches, The <br /> minimum required stair tread width is 9 inches. The <br /> maximum stair rise is 8 inches. When risers are <br /> closed, all treads may have a uniform projection not to <br /> exceed 1 and 1/2 inches, The greatest riser height shall <br /> not exceed the smallest by more than 2/8 inch. (R-213,1) <br />8, Handrails meeting the following requirements shall be <br /> provided on at least one side of stairways of more than <br /> <br /> <br />