BUILD - 1594293
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1594293
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2013 2:31:37 PM
Creation date
2/15/2005 12:35:23 PM
Metadata
Fields
Template:
Permits
Permit Address
10695 JAMES WAY DR SE
Permit City
Aumsville
Permit Number
555-99-01338
Parcel Number
081W29C 00900
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
BUILDING PERMIT <br />DATE/TIME 04/15/99 14~21 <br />TYPE Resident, addition/alteration <br />OCCUPANCY R-3 <br />CONST TYPE V-N <br />UGB~ SITE: FD <br /> <br />PERMIT NO <br />STATUS <br />ISSUED <br />TO EXPIRE <br />PAGE <br /> <br />99-01338 <br />ISSUED <br />04/15/1999 <br />10/12/1999 <br /> 2 <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 10 Right: 10 Rear: 20 Special: <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 222 1987). <br />2. THIS PLAN REVIEW WAS COMPLETED BY D, MARET ON 2-12-99, <br />3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or oF noncompliance with any <br /> applicable regulations of local government, <br />4. BATHROOM LIGHT / VENT, Bathrooms, water closet compartments <br /> and other similar rooms shall be provided with a window of <br /> not less than 3 square feet, one half of which must be <br /> openable, or artificial light and an approved mechanical <br /> ventilation system capable of producing a change of air <br /> every 12 minutes, [Sec. 303,2] <br />5. SMOKE DETECTORS / ALTEPJ~TIONS, When alterations, repairs or <br /> additions requiring a permit occur, or when sleeping rooms <br /> are added or created, the entire building shall be provided <br /> with smoke detectors located as required for new dwellings: <br /> the smoke detectors shall be interconnected and hard wired, <br /> EXCEPTION: Detectors shall not be required to be inter- <br /> connected and hard wired where the alterations, repairs, or <br /> additions do not result in the exposure of electrical wiring <br /> by the removal of interior wall and ceiling finishes, <br /> [Sec. 316.1.1] <br />6, STAIRWAYS shall not be less than 36 inches in clear width at <br /> all points between the handrail height and the required <br /> minimum headroom of 6 feet 8 inches. Minimum width from the <br /> handrail down is 82 incheswith one handrail, 28 inches with <br /> two. The minimum required stair tread width is 9 inches, <br /> The maximum stair rise is 8 inches, When risers are closed, <br /> all treads less than lO inches shall have a uniform nosing <br /> betweem 3/4 inches and 1 1/4 inches, The greatest riser <br /> height/tread depth shall not exced th smallest by more than <br /> 3/8 inch. [Sec. 314.1: 314.2: 314.2.1: 314.3] <br />7. ALL INTERIOR STAIRS shall be provided with a minimum of 60 <br /> watts of incandescent light or other artificial light source <br /> rated at a minimum of 850 lumens, Interior stairs of six <br /> steps or more shall have the required lighting located in <br /> the in~ediate vicinity of the top and bottom of the stairs, <br /> and the required lighting shall be controlled from the top <br /> and bottom of stairs provided the artificial light source is <br /> located directly over each stair section, [Section 302.4] <br />8. GUARDP~qILS AND HANDRAILS shall be able to resist a single <br /> concentrated load of 200 pounds applied in any direction at <br /> any point along the top. [Table 301,4] <br />9. CONCRETE SPECIFICATIONS. Basement walls and foundations not <br /> exposed to the weather, basement slabs and interior slabs on <br /> grade, except garage floor and steps exposed to the weather <br /> shall have a minimum compressive strength of 2500 psi. <br /> Basement walls, foundation walls, exterior walls, and other <br /> veritical concrete work exposed to the weather, porches, <br /> carport slabs, and steps exposed to the weather, and garage <br /> floor slabs shall have a minimum specified compressive <br /> strength of 8000, Concrete shall be air entrained, Total <br /> air content (percent by volume of concrete) shall not be <br /> less than 5 percent or more than 7 percent, [Sec. 402,2. <br /> Table 402.2] <br />lO. WATERPROOFING REQUIRED. Foundation walls enclosing <br /> habitable or storage space shall be waterproofed, <br /> [Sec. 406.2] <br />11. CRAWL HOLE. Provide an access crawl hole to the underfloor <br /> space, The minimum size opening required is 18 inches by 24 <br /> <br /> <br />