Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: <br /> <br />SITE: <br /> <br />11. <br /> <br />12. <br /> <br />13, <br /> <br />14. <br /> <br />15. <br /> <br />16. <br /> <br /> DWELLING PERMIT <br /> 04/07/99 12:12 PERMIT NO 99-01979 <br /> New Single Family Dwelling STATUS ISSUED <br /> R-3 ISSUED 04/07/1999 <br /> V-N TO EXPIRE 10/04/1999 <br /> PAGE 3 <br />minimum headroom of 6 feet 8 inches. Minimum width from the <br />handrail down is 32 inches with one handrail, 28 inches with <br />two. The minimum required stair tread width is 9 inches. <br />The maximum stair rise is 8 inches. When risers are closed, <br />all treads less than 10 inches shall have a uniform nosing <br />betweem 3/4 inches and i 1/4 inches. The greatest riser <br />height/tread depth shall not exced th smallest by more than <br />2/8 inch. [Sec. 314,1; 214.2: 314,2.1: 314.3] <br />HANDRAILS having a minimum and maximum height of 30 inches <br />and 28 inches, respectively, shall be provided on at least <br />one side of stairways of more than three risers, All re- <br />quired handrails shall be continuous the full lengt~ of the <br />stairs. Ends shall be returned or shall terminate in newel <br />posts or safety terminals. Exception: Handrails may be <br />interrupted by a newel post at a turn, and the use of a <br />volute turnout or starting easing shall be allowed over the <br />lowest tread. [Sec, 315.1] <br />THE HANDGRIP PORTION of handrails shall not be less than <br />1 1/4 inches or more than 2 5/8 inches in cross-sectional <br />dimension, or the shape shall provide an equivalent gripping <br />surface, The handgrip portion shall have a smooth surface <br />and edges shall have a minimum radius of 1/8 inch, <br />[Section 315.2] <br />FIRESTOPPING shall be provided in the following locations, <br />1. In concealed spaces of stud walls, including furred <br /> spaces not to exceed 10 feet horizontally, and at the <br /> ceiling and floor level. <br />2. At all interconnections between concealed vertical and h <br /> horizontal spaces such as occur at soffits, drop or cove <br /> ceilings, etc. <br />3, In concealed spaces between stair stringers at the top <br /> and bottom of the run and wall cavities in line with the <br /> stringers; <br />4. At openings around vents, pipes, ducts, chimneys, fire- <br /> places at ceilings/floor level, w/non-combustible materials, <br /> HEATING AND COOLING applicances located in a garage shall be <br /> protected from impact by automobiles. [Sec, 1307.3] <br /> DECORATIVE GAS APPLIANCES shall be listed and installed in <br /> accordance with their listing and the manufacturer's <br /> installation instructions. [Sec, 2205] <br />EXTERIOR JOINTS around windows and door frames, between wall <br />cavities and window or door frames, between wall and <br />foundation, between wall and roof. between wall panels, at <br />penetrations or utility services through walls, floors and <br />roofs and all other openings in the exterior envelope shall <br />be sealed in a manner approved by the Building Official. <br />(E40t.8.2] <br /> <br /> <br />