My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1613399
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1613399
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2013 3:56:24 PM
Creation date
4/3/2005 12:30:33 PM
Metadata
Fields
Template:
Permits
Permit Address
14322 STENBOCK WY NE
Permit City
Aurora
Permit Number
555-99-03594
Parcel Number
041W02D 70000
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CDNST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br />02/23/00 11:28 PERMIT NO <br />Commercial addition/alteration STATUS <br />R-3 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />99-03594 <br />ISSUED <br />02/22/2000 <br />08/21/2000 <br /> 2 <br /> <br />REQUIRED SETBACKS: Front: <br /> <br />PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br /> Left: Right: Rear: <br /> <br />Special: <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br />2. THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 10/04/99. <br />3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br />4. This project may be subject to the architectural standards <br /> of the Americans with Disabilities Act of 1990 (ADA), <br /> Issuance of a building permit does not certify compliance <br /> with this Federal Statute. Copies of the guidelines and <br /> information concerning the ADA may be obtained from the <br /> Architectural and Transportation Barriers Compliance Board, <br /> 1-202-653-7834 (Voce/TDD) or 1-800-USA-ABLE. Failure to <br /> comply with the ADA may result in Federal fines and <br /> penalties. <br /> <br />5, Local Fire Districts may have additional requirements that <br /> affect this project, You are advised to contact the Fire <br /> District before you proceed, <br /> <br />6. This is a plan review covering the alterations to the above <br /> existing building. This review is based on the regulations <br /> of the Oregon State Structural Specialty Code ('97 UBC) <br /> 1998 Edition, <br /> <br /> 7. OCCUPANCY CLASSIFICATION. <br /> The TENANT IMPROVEMENT space is classified as a Group R, <br /> Division 8 Occupancy, dwelling unit (caretaker residence). <br /> <br /> 8, OCCUPANCY SEPAP. ATION. (OSSC Sec 202.4i <br /> A one-hour fire-resistive occupancy separation shall be <br /> provided between the R-2 Dwelling Unit and the existing <br /> S-5 Aircraft Hangar. <br /> A one-hour fire-resistive occupancy separation shall be of <br /> less than one-hour fire-resistive construction. <br /> All openings in such separation shall be protected by a <br /> fire assembly having a one-hour fire-protection rating, <br /> Where the occupancy separation is horizontal, structural <br /> members supporting the separation shall be protected by <br /> equivalent fire-resistive construction, <br /> <br />9. TYPE OF CONSTRUCTION. (OSSC Sec 603.1i <br /> The existing building has been classified as TYPE tI-N <br /> CONSTRUCTION. therefore, materials used shall be as follows: <br /> * Structural Elements - noncombustible materials. <br /> * Floors - noncombustible materials, provided however, that <br /> a wood surface or finish may be applied over <br /> such noncombustible materials, <br /> * Walls & Permanent Partitions - noncombustible materials. <br /> <br />10. PROVIDE APPROVED ASSEMBLY DOCUMENTATION, <br /> The plans submitted proposed the steel tube columns support- <br /> ing the the floor/ceiling assembly will be wrapped with <br /> 5/8" Type X gypsum board to comply with the one-hour <br /> fire-resistive occupancy separation construction. <br /> <br /> PROVIDE DOCUMENTATION SPECIFYING THAT THE PROPOSED <br /> ASSEMBLY HAS BEEN TESTED AND APPROVED THROUGH RECOGNIZED <br /> STANDARDS. THIS DOCUMENTATION MUST BE SUBMI1-FED PRIOR <br /> TO THE INSTALLATION OF THE COLUMNS, <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.