My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SESPNEW - 1614641
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
SESPNEW - 1614641
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2018 3:11:20 PM
Creation date
4/3/2005 12:51:39 PM
Metadata
Fields
Template:
Permits
Permit Address
14369 KEIL RD NE; 14397 KEIL RD NE
Permit City
Aurora
Permit Number
555-99-04990
Parcel Number
041W11A 80003
Permit Type
SESPNEW
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME : 06/29/99 17:06 <br />TYPE : SP <br /> <br />SITE EVALUATION/SEPTIC PERMIT <br /> PERMIT NO <br /> STATUS <br /> ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />99-04990 <br />ISSUED <br />06/29/1999 <br />06/28/2000 <br />2 <br /> <br />SIlE EVALUATION APPROVAL AND SEPTIC PERMIT <br /> <br />This property has been evaluated for the feasibility of the installation of a septic <br />system for a COMMERCIAL building site, Based on the results of this study, site evaluation <br />approval was granted, The approval is specific to the area tested, and the septic system must be <br />located in the immediate area of the test pits, unless otherwise authorized by this office. A <br />new site evaluation may be required if the system is proposed for a different area on the property. <br /> <br />This approval is given on the basis that the lot or parcel will not be further partitioned <br />or subdivided and that conditions on this property and on adjacent properties are not altered in <br />any manner which would prohibit the issuance of a permit. Soils in the approved area shall not be <br />altered or modified by cutting, filling, or other developmental activities which would impede the <br />successful operation of the initial or replacement soil absorption systems. Failure bo comply with <br />the above items may void this approval, <br /> <br />This site evaluation approval runs with the land, but the permit is non-transferable and <br />non-refundable, <br /> <br />Keep this document with your records, Show this permit to the septic installer prior to <br />installation of the system, Any deviation from the approved plan must have prior approval from <br />this office. <br /> <br />The following construction specifications shall apply to the installation of the initial <br />septic system: <br /> <br />TYPE OF INITIAL SYSTEM: STANDARD <br /> <br />MINIMUM SEPTIC TANK CAPACITY: 1000 GALLONS <br /> LINEAL FEET OF Dt~J~INFIELD: 150 <br /> TYPE OF DISTRIBUTION: EQUAL <br /> DISPOSAL TRENCH DEPTH: 18INCHES, MINIMUM; 24INCHES, MAXIMUM <br /> TOTAL DRAIN MEDIA DEPTH: 12INCHES <br /> DRAIN MEDIA UNDER PIPE: 6INCHES <br /> MINIMUM SOIL BACKFILL: 12INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> <br /> The disposal trenches are constructed (2) feet wide and on mimimum ten (10) foot centers <br /> and with no line exceeding 125 feet in length. The trenches and perforated pipe are <br /> installed level (+/- one inch) and contoured to follow the natural ground surface, <br /> <br />TYPE OF FUTURE REPLACEMENT SYSTEM: STANDARD <br /> <br />COMMENTS AND CONDITIONS <br /> <br />1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> AI~FENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center, Those rules are <br /> set forth in OAR 952-00t-0010 through OAR 952-001-0090, You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br />2, THIS SEPTIC REVIEW WAS COMPLETED BY Z,EWING ON 9/22/98, THE <br /> SITE IS APPRQVED FOR A STANDARD DRAINFIELD SYSTEM TO SERVE <br /> THE EXISTING HANGAR BUILDING ON THE PROPERTY. THE SYSTEM IS <br /> SIZED FOR A 150 GALLON PER DAY FLOW. <br /> NOTE: A SEPTIC PUMP MAY BE REQUIRED IF THE SHALLOW TRENCH <br /> DEPTH CANNOT BE MAINTAINED, <br />3, THE A~ACHED ORANGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspection. The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site, <br />4, THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> vehicular traffic, livestock and farming activities. Other <br /> activities such as logging, excavating or filling, driveway <br /> placement or any similar activities may also damage the soil <br /> <br /> <br />