My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1615046
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1615046
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2010 2:13:45 PM
Creation date
4/3/2005 12:58:35 PM
Metadata
Fields
Template:
Permits
Permit Address
20257 GRIM RD NE
Permit City
Aurora
Permit Number
555-99-05268
Parcel Number
041W22B 01500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />1D/26/99 ll:B1 PERMIT NO <br />New Commercial STATUS <br />E-1 ISSUED <br />V-N TO EXPIRE <br /> PAGE <br /> <br />99-05268 <br />ISSUED <br />10/26/1999 <br />04/23/2000 <br /> 2 <br /> <br /> PLAN REVIEW CO~MENTS AND CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: 20 Left: 20 Right: 20 Rear: 20 Special: <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987). <br /> 2. THIS PLAN REVIEW WAS COMPLETED BY T COLEMAN ON 10/12/99. <br /> 3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government, <br /> 4, This is a Plan Review covering the construction of the <br /> above indicated new building, Plans have been reviewed for <br /> compliance with the provisions of the Oregon State <br /> Structural Specialty Code ('97 UBC) 1998 Edition. <br /> THIS REVIEW IS FOR THE 54.900 SQUARE FOOT PRIMARY SCHOOL, <br /> THIS BUILDING IS SUBDIVIDED BY 3 - 2-HR AREA SEPA~TION <br /> WALLS, <br /> 5, DRAFT STOPS IN ATTICS SHALL SUBDIVIDE THE BUILDING INTO <br /> AREAS NOT GREATER THAN 3,000 SQ. FT. <br /> HORIZONTAL SPACING OF DRAFT STOPS SHALL NOT EXCEED 60 FT, IN <br /> EITHER DIRECTION. <br /> 6, SEE REVISED FRAMING DETAILS AT 2-HOUR AREA SEPARATION WALLS <br /> BY LEWIS & VAN VLEET INC. DATED 8/25/99 CONTAINING SHEETS <br /> R1 THROUGH R15, <br /> SUBSTITUTION OF SOLID WOOD BLOCKING WITHIN THE 1-HOUR ATTIC <br /> ASSEMBLIES HAS BEEN ACCEPTED AS AN ALTERNATE METHOD TO <br /> EXTENDING THE TWO LAYERS OF GYPSUM WALLBOARD TO THE UNDER- <br /> SIDE OF THE ROOF SHEETING, THIS WAS DEEMED NECESSARY TO <br /> MAINTAIN THE STRUCTURAL CAPACITY OF THE WALL AND NOT ALLOW- <br /> ING STRUCTURAL MEMBERS TO PASS THROUGH THE 2-HOUR AREA <br /> SEPARATION WALLS, <br /> 7. CONTACT PERSONS <br /> <br /> ARBUCKLE COSTIC ARCHITECTS <br /> WALTER BENSMAN <br /> 363 STATE ST, SALEM, OR 97201-3533 <br /> JASON CANE, DEPUTY STATE FIRE MARSHAL <br /> 4760 PORTLAND RD NE, SALEM, OR 97305 <br /> 8. An approved water supply capable of supplying the required <br /> fire flow for fire protection shall be provided to all <br /> premises, (UFC 903.2) In setting the requirements for fire <br /> flow, the chief may be guided by Appendix III-A (1997 UFC, <br /> 1998 OUFC) <br /> 9, Buildings under construction shall be in accordance with <br /> Article 87 of the Fire Code, Fire protection shall be <br /> provided in accordance with UFC Section 1BO4. <br />10, Portable fire extinguishers shall be provided and installed <br /> in occupancies and locations as set forth in the Fire Code <br /> and as required by the chief. (UFC 1002) <br />11. The mechanical and electrical plans are not covered by this <br /> review, Mechanical and electrical systems are required to <br /> be in compliance with applicable codes, <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.