My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1615046
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1615046
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2010 2:13:45 PM
Creation date
4/3/2005 12:58:35 PM
Metadata
Fields
Template:
Permits
Permit Address
20257 GRIM RD NE
Permit City
Aurora
Permit Number
555-99-05268
Parcel Number
041W22B 01500
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
OFFICE OF THE STATE FIRE MARSHAL <br /> REVIEW CHECK <br /> <br /> [] General Plans Review · Fire Alarm Review <br /> <br />Building: North Marion Primary School <br /> <br />Address: 202__ Grim Rd. NE; Aurora 97002-9499 <br /> <br />Owner: North Marion School District 15 <br /> <br />Address: 20256 Grim Rd. NE; Aurora 97002-9499 <br /> <br />[] Sprinkler System Review <br /> <br /> County: Marion <br /> Occupancy: El, E3, A2.1 <br /> BO Activity #: 99-05258, <br /> <br /> 99-05259, 99-05264, <br /> 99-05266, 99-05268 <br /> <br />COMMENT: This plan check is based on the 1998 Oregon Uniform Fire Code (UFC), the 1997 <br />edition of the Uniform Fire Code Standards, and the 1997 edition of the National Fire Codes <br />(NFC). <br /> <br />1) The design, installation and testing of the fire alarm system shall comply with the 1997 NFC, <br /> (NFPA 72-1996). <br /> <br />2) Group A Occupancy portions of the building shall comply with the requirements for the <br /> Group E Occupancy. (UFC 1007.2.2.1, Exception 2) <br /> <br />3) Provide connection of smoke detectors and kitchen hood, or other extinguishing system, to <br /> the building fire alarm system (UFC 1007.2.1.2, 1007.2.4.1, NFPA 72-Par. 5-7). <br /> <br />4) Provide spacing of visual appliances within rooms using the appropriate spacing, candela <br /> ratings and number of appliances in accordance with NFPA 72-1996, Sections 6-3 and 6-4. <br /> Provide minimum spacing or synchronization for more than two visual appliances within a <br /> room or within any field of view. (NFPA72, 6-4.4.1.1). (Sheet E3.30, Library; Sheet 3.31, <br /> Multi-purpose room at both sides of divider when open or closed; rooms in general) <br /> <br />(continued on next page) <br /> <br />Ken Fuglee, Deputy State Fire Marshal 1 <br />Office Of State Fire Marshal <br />4760 Portland Rd. NE, Salem, OR. 97305-1760 <br />(503)373-1540 x253 <br />7/20/99 <br />MBO9905258primFA <br /> <br />Working Smoke Detectors Save Lives <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.