Laserfiche WebLink
SEPTIC PERMIT <br />DATE/TIME ~ 08/23/99 09~48 PERMIT NO <br />TYPE : SP STATUS <br /> ISSUED <br /> TO EXPIRE <br /> PAGE <br /> <br />99-05509 <br />ISSUED <br />08/23/1999 <br />08/22/2000 <br />2 <br /> <br />SEPTIC PERMIT <br /> <br />This property was previously evaluated 00/00/0000 for the feasibility to install a <br />septic system for a RESIDENTIAL building site. Based on the results of this study, site <br />approval was granted, The approval is site specific to the area tested, and the septic <br />system must be located in the immediate area of the test pits, unless otherwise authorized <br />by this office. A new site evaluation may be required if the system is proposed for a <br />different area on the property, <br /> <br />This approval was given on the basis that the lot or parcel will not be further partitioned <br />or subdivided and that conditions on this property and on adjacent properties are not altered <br />in any manner which would prohibit the issuance of a permit. Soils in the approved area <br />shall not be altered by cutting, filling, or other developmental activities which would <br />impede the successful operation of the initial or replacement absorption systems, Failure <br />to comply with the above items may void this approval. <br /> <br />The site evaluation approval runs with the land, but the permit is non transferable and non- <br />refundable, <br /> <br />Keep this document with your records. Show this permit to the septic installer prior to <br />installation of the system. Any deviation from the approved plan must have prior approval from <br />this office. <br /> <br />The following construction specifications shall apply to the installation of the initial <br />septic system: <br /> <br />TYPE OF INITIAL SYSTEM: <br /> <br />MINIMUM SEPTIC TANK CAPACITY: 1000 GALLONS <br /> LINEAL FEET OF DRAINFIELD: ~50 <br /> TYPE OF DISTRIBUTION: EQUAL <br /> DISPOSAL TRENCH DEPTH: 18INCHES, MINIMUM: 20INCHES. MAXIMUM <br /> TOTAL DPJNIN MEDIA DEPTH: 12INCHES <br /> DRAIN MEDIA UNDER PIPE: BINCHES <br /> MINIMUM SOIL BACKFILL: 6INCHES <br /> GROUND WATER INTERCEPTOR: N <br /> <br />The disposal trenches are constructed two (2) feet wide and on minimum ten (10) foot centers <br />and with no line exceeding 125 feet in length, The trenches and perforated pipe are <br />installed level (+/- one inch) and contoured to follow the natural ground surface. <br /> <br />TYPE OF FUTURE REPLACEMENT SYSTEM: STANDARD <br /> <br />COMMENTS AND CONDITIONS <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW, <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 222-.1987). <br />2, THIS SEPTIC REVIEW WAS COMPLETED BY Z.EWING ON 8/17/99. THE <br /> EXISTING LOTS IS APPROVED FOR A STANDARD DRAINFIELD REPLACE- <br /> MENT. THE SITE IS SOMEWHAT WET IN THE WINTER SO THE NEW <br /> DRAINFIELD LINES SHOULD BE INSTALLED AS SHALLOW AS POSSIBLE, <br /> IF ANY OF THE OLD DRAINFIELD LINES ARE ENCOUNTERED WHEN IN- <br /> STALLING THE NEW LINES, CARE SHOULD BE TAKEN TO ABANDON THEM <br /> TO PREVENT "SHORT CIRCUITING" OF THE EFFLUENT, THE ABANDON- <br /> MENT OF THE OLD TANK HAS BEEN DONE AND FORM SUBMITTED, <br />3. THE ATTACHED ORANGE CARD MUST BE POSTED AT THE COUNTY ROAD <br /> prior to requesting an inspectign, The card must be located <br /> near the driveway to the property to assist the inspector in <br /> locating the access onto the site. <br />4, THE APPROVED SEPTIC SYSTEM AREA MUST BE PROTECTED from any <br /> vehicular traffic, livestock and farming activities. Other <br /> activities such as logging, excavating or filling, driveway <br /> <br /> <br />