DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />10/07/99 16:32 PERMIT NO <br />New Commercial STATUS <br />S-2 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />99-06760 <br />ISSUED <br />10/07/1999 <br />04/04/2000 <br /> 2 <br /> <br /> PLAN REVIEW COMMENTS ANB CONDITIONS <br /> <br />REQUIRED SETBACKS: Front: Left: Right: Rear: <br /> OK AS PER SITE PLAN <br /> <br /> 1. CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center. <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (502) 232-1987). <br /> 2, THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 09/30/99. <br /> 3. Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> 4. This project may be subject to the architectural standards <br /> of the Americans with Disabilities Act of 1990 (ADA). <br /> Issuance of a building permit does not certify compliance <br /> with this Federal Statute. Copies of the guidelines and <br /> information concerning the ADA may be obtained from the <br /> Architectural and Transportation Barriers Compliance Board, <br /> 1-202-653-7834 (Voce/TDD) or 1-800-USA-ABLE, Failure to <br /> comply with the ADA may result in Federal fines and <br /> penalties. <br /> <br /> 5. Local Fire Districts may have additional requirements that <br /> affect this project, You are advised to contact the Fire <br /> District before you proceed, <br /> <br /> 6, This is a Plan Review covering the construction of the <br /> above indicated new building, Plans have been reviewed for <br /> compliance with the provisions of the Oregon State <br /> Structural Specialty Code ('97 UBC) 1998 Edition. <br /> <br /> THIS BUILDING HAS A MIXED OCCUPANCY CLASSIFICATION. <br /> THE OCCUPANCY CLASSIFICATIONS ARE AS FOLLOWS: F 1/F-2/S-2/B. <br /> <br /> THIS BUILDING HAS TWO 2-HOUR AREA SEPARATION WALLS LOCATED <br /> BETWEEN THE F-1 & F-2 OCCUPANCIES AND BETWEEN THE F-2 & S-2 <br /> OCCUPANCIES. <br /> <br /> 7. BUILDING CODE SUMMARY. <br /> Occupancy Classification: F-1/F-2/S-3 & B. <br /> Type of Construction: II-N <br /> Basic Allowable Area: F-l: 12,000 sf <br /> F-2:18,000 sf <br /> S-2:18,000 sf <br /> Proposed: S-2 / 1st Flr: 21,800 sf / 2nd Flr: 9,475 sf <br /> F-2 / 1st Flr: 16,500 sf <br /> F-1 / 1st Flr: lO,O00 sf / 2nd Flr: 5,000 sf <br /> TOTAL AREAS: 48,200 SF I4,475 SF <br /> NOTE: Allowable Area Increase: 1-1/4% for 2 sides. <br /> <br /> 8. BUILDING YARDS, <br /> <br /> NORTH: 90'-0" to proposed BLDG C. <br /> SOUTH: 65'-10" to Property Line PLUS 60 ft R.O,W Keil Rd <br /> EAST: 5'-0" to Property Line. <br /> WEST: 30'-0" to Property Line. <br /> <br /> 9. ALLOWABLE AREA INCREASES. (OSSC Sec 505i <br /> The floor areas specified in Section 504 may be increased by <br /> employing the provisions of SEPARATION ON THREE SIDES. <br /> Where public ways or yards more than 20 feet in width extend <br /> along and adjoin two sides of the building, floor areas may <br /> be increased at a rate of 2-1/2 percent for each foot by <br /> which the minimum width exceeds 20 feet, but the increase <br /> shall not exceed 100 percent, <br /> WEST YARD: 30 feet minus 20 equals lO, <br /> <br />Special: <br /> <br /> <br />