DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br /> 10/07/99 16:32 PERMIT NO <br /> New Commercial STATUS <br /> S-2 ISSUED <br /> II-N TO EXPIRE <br /> PAGE <br /> 10 times 2-1/2% equals 25 percent increase <br /> Basic Allowable: 18,000 sf (1,25%): 22,500 sf <br /> <br />10, LOCATION ON PROPERTY, (OSSC Sec 503i <br /> Exterior walls shall have fire resistance and opening <br /> protection as set forth in TABLE 5-A and in accordance with <br /> such additional provisions as are set forth in Chapter 6. <br /> Distances shall be measured at right angles from the <br /> property line. <br /> F-I/II-N: Exterior Walls: One-Hour less than 20 feet. <br /> F 2 & S-2/II-N: Exterior Walls: One-Hour less than 5 feet, <br /> F-l, F-2 & S-2/II-N: Openings: <br /> Not permitted less than 5 feet. <br /> Protected less than 10 feet. <br /> <br />11. AREA SEPARATION WALLS. (OSSC Sec 504.6i <br /> Each portion of a building separated by one or more area <br /> seapartion walls that comply with the provisions of this <br /> section may be considered a separate building. The extent <br /> and location of such area separation walls shall provide a <br /> complete separation. <br /> When an area separation wall also separates occupancies that <br /> are required to be separated by an occupancy separation, the <br /> most restrictive requirements of each separation shall apply <br /> <br />12, AREA SEPARATION FIRE RESISTANCE & OPENINGS. (OSSC Sec 504.6i <br /> Area separation walls shall not be less than two-hour fire- <br /> resistive construction in TYPE II-N buildings. The total <br /> width of all openings in such walls shall not exceed 25 <br /> percent of the length of the wall in each story. <br /> All openings shall be protected by a fire assembly having a <br /> one- and one-half-hour fire protection rating in two-hour <br /> fire-resistive walls, <br /> <br />13. AREA SEPARATION WALL TERMINATION. (OSSC Sec 540.6i <br /> Area separation walls shall extent vertically from the <br /> foundation to a point at least 30 inches above the roof. <br /> EXCEPTIONS: <br /> 1. Any area separation wall may terminate at the underside <br /> of the roof sheathing, deck or slab. provided the roof- <br /> ceiling assembly is of at least two-hour fire-resistive <br /> construction. <br /> <br />14. AREA SEPARATION WALL TERMINATION, cont'd: <br /> EXCEPTIONS, cont'd: <br /> 2. Two hour area separation walls may terminate at the <br /> underside of the roof sheating, deck or slab, provided: <br /> 2.1 When the roof-ceiling framing elements are parallel to <br /> the walls, such framing and elements supporting such <br /> framing shall not be of less than one-hour fire- <br /> resistive construction for a width of not less than <br /> 5 feet on each side of the wall. <br />15. AREA SEPARATION WALL TERMINATION, cont'd: <br /> EXCEPTIONS. cont'd: <br /> 2.2 When roof-ceiling framing elements are are parallel to <br /> the walls, the entire span of such framing and element <br /> s supporting such framing shall not be of less than <br /> one-hour fire-resistive construction. <br /> 2,3 Openings in the roof shall not be located within 5 <br /> feet of the area separation wall. <br /> 2,4 The entire building shall be provided with not less <br /> than Class B roof assembly as specified in TABLE 15-A. <br /> <br />16, AREA SEPARATION WALL TERMINATION, cont'd: <br /> EXCEPTIONS, cont'd: <br /> 3. Two-hour area separation walls may terminate at the <br /> underside of noncombustible roof sheathing, deck or <br /> slabs of roofs of noncombustible construction, provide: <br /> 3.1 Openings in the roof are not located within 5 feet of <br /> the area separation wall. <br /> 3.2 The entire building is provided with not less than a <br /> Class B roofing assembly as specified in TABLE 15-A. <br /> <br />99-06760 <br />ISSUED <br />10/07/1999 <br />04/04/2000 <br /> 3 <br /> <br /> <br />