BUILD - 1616649
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1616649
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2013 2:48:17 PM
Creation date
4/3/2005 1:23:42 PM
Metadata
Fields
Template:
Permits
Permit Address
14401 KEIL RD NE
Permit City
Aurora
Permit Number
555-99-06760
Parcel Number
041W11A 00200
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br /> 10/07/99 16:32 PERMIT NO 99-06760 <br /> New Commercial STATUS ISSUED <br /> S-2 ISSUED 10/07/1999 <br /> II-N TO EXPIRE 04/04/2000 <br /> PAGE 6 <br /> Friday, July 26, 1991: 28 CFR, Part 36, including Americans <br /> with Disabilities Act Accessibility Guidelines (ADAAG) and <br /> Public Law 100-430, the Fair Housing Act (FHA) and the <br /> regulations adopted thereunder and the requirements of OSSC <br /> Chapter 11, <br /> <br />33. SPECIAL INSPECTIONS. (OSSC Sec 1701i <br /> Except as provided in Section 1701.1, the types of work <br /> listed below shall be inspected by a special inspector. <br /> 1. Concrete, See exceptions. <br /> 2, Bolts installed in concrete, <br /> 3, Special moment-resisting concrete frames. <br /> 4. Reinforcing steel & Prestressing steel tendons, <br /> See exception. <br /> 5, Structural welding, See exceptions, <br /> 6, High-strngth bolting. <br /> 7. Structural masonry, <br /> <br />34, SPECIAL INSPECTIONS, cont'd: <br /> In addition to the inspection required by Section 108, the <br /> owner or the engineer or architect of record acting as the <br /> owner's agent shall employ one or more special inspectors <br /> who shall provide inspections during construction on the <br /> types of work listed above. <br /> NOTE: THE SPECIAL INSPECTORSHALL BE LISTED IN THE MOST <br /> CURRENT OREGON BUILDING OFFICIALS ASSOCIATION ROSTER, <br /> A copy of this roster can be obtained from this office <br /> upon request. Special inspection reports shall comply <br /> with Section 1710,3 & OBOA Special Inspector Roster, <br /> <br />35. ARCHITECT OF RECORD, <br /> The architect of record for this project: <br /> <br /> Aron Faegre <br /> License No.: 2347 ' <br /> 520 S.W. Yamhill <br /> Portland, OR 97204 <br /> Ph: (503) 222-2546 <br /> <br />36, STRUCTURAL ENGINEER - FOUNDATION. <br /> The structural engineer for this project: <br /> <br /> Dirk Looijenga <br /> Certificate No,: 04175PE <br /> 4621 S.W, Corbert Ave. <br /> Portland, OR 97201 <br /> Ph: (503) 224-6788 <br /> Fax: (503) 224 5544 <br /> <br />37. PRE-ENGINEERED METAL BUILDING SUPPLIER. <br /> The pre-engineered metal building supplied by: <br /> <br /> Butler Manufacturing Company <br /> Joseph W, Lowe, P,E. <br /> Certificate No~: 08656PE <br /> P.O. Box I590 <br /> Visalia, CA 93291 <br /> <br />38. MEZZANINE/SECOND FLOOR DESIGN. <br /> The second floor was designed by: <br /> <br /> DEVCO Engineering, Inc, <br /> David R, Conklin. P.E. <br /> Certificate No,: 13952PE <br /> 245 NE Conifer <br /> PO Box 1211 <br /> Corvallis, OR 97329 <br /> Ph: (541) 757-8991 <br /> Fax: (541) 757-9885 <br /> <br />39. KEEP CONSTRUCTION SITE CLEAN OF EXCESSIVE FLAMMABLE DEBRIS, <br /> e,g. SCRAP PILES THAT MAY INCLUDE WOOD, INSULATION, PAPER, <br /> <br /> <br />