My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1616649
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1616649
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2013 2:48:17 PM
Creation date
4/3/2005 1:23:42 PM
Metadata
Fields
Template:
Permits
Permit Address
14401 KEIL RD NE
Permit City
Aurora
Permit Number
555-99-06760
Parcel Number
041W11A 00200
Permit Type
BUILD
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />24~ <br /> <br />25, <br /> <br />26. <br /> <br />27~ <br /> <br />28~ <br /> <br />29. <br /> <br />30~ <br /> <br />31. <br /> <br />32. <br /> <br />10/07/99 16:22 PERMIT NO <br />New Commercial STATUS <br />S-2 ISSUED <br />II-N TO EXPIRE <br /> <br /> PAGE <br />FIRE FLOW, (OUFC Sec 903) <br />An approved water supply capable of supplying the required <br />fire flow for fire protection shall be provided to all <br />premises upon which facilities, buildings are constructed. <br />When any portion of the facility or building protected is tn <br />excess of 150 feet from a water supply on a public street. <br />as measured by an approved route around the exterior of the <br />facility or building, on-site fire hydrants and mains <br />capable of supplying the required fire flow shall be <br />provided when required by the chief. <br /> <br />FIRESAFETY DURING CONSTRUCTION, (OUFC Sec 8704i <br />Buildings under construction shall be in accordance with <br />with Article 87 of the Fire Code. <br />Fire department access roads shall be established and <br />maintained, <br />Water mains and hydrants shall be installed and operational. <br />Combustible debris shall not be accumulated within buildings <br />Combustible debris, rubbish and waste materials shall be <br />removed as often as practical. <br />Combustible debris, waste material and trash shall not be <br />burned on the site unless approved. <br /> <br />EXIT SIGNS~ (OSSC Sec 1003.2.8i <br />The path of exit travel to and within exits in a building <br />shall be identified by exit signs conforming to the require- <br />ments of Section 1003,2.8. Exit signs shall be readily <br />visible from any direction of approach. Exit signs shall be <br />located as necessary to clearly indicate the direction of <br />egress travel, No points shall be more than 100 feet from <br />the nearest visible sign, See Exceptions. <br /> <br />STAIRWAY LANDINGS. (OSSC Sec 1003.3.3.5i <br />At least one intermediate landing shall be provided for each <br />12 feet of vertical stairway rise measured between the <br />horizontal planes of adjacent landings. <br /> <br />EXIT CONTINUITY. (OSSC Sec 1003.2.5i <br />The path of travel along a means of egress shall not be <br />interrupted by any building element other than a means of <br />egress component as specified in this chapter. Obstructions <br />shall not be placed in the required width of a means of <br />egress except projections permitted by this chapter. The <br />required capacity of a means of egress system shall not be <br />diminished along the path of travel. <br /> <br />TRAVEL THROUGH INTERVENING ROOMS. (OSSC Sec 1004.2,1i <br />The required access to exits from any portion of a building <br />shall be directly from the space under consideration to an <br />exit or to a corridor that provides direct access to an exit <br /> Exit access shall not be interrupted by intervening rooms <br /> Hallways shall be considered as intervening rooms, A <br /> means of egress shall not pass through kitchens, storerooms, <br /> restrooms, closets or spaces used for similar purposes. <br /> <br />EXIT COMPONENTS. (OSSC Sec 1005.2i <br />Doors of ,exit componrnts that open directly to the exterior <br />of a building shall not be located in areas where openings <br />are not permitted due to location on property by TABLE 5-A, <br /> <br />TYPE OF CONSTRUCTION. (OSSC Sec 603i <br />Floor construction of Type II-N buildings shall be of <br />noncombustible material, provided, however; that a wood <br />surface or finish may be applied over such noncombustible <br />material, <br /> <br />ACCESSIBILITY. (OSSC Sec 1101i <br />This site. building and facilities are required to be <br />accessible to and useable by persons with disabilities. <br />Details and dimensions not shown on the plans shall comply <br />with Public Law 101-336. the Americans with Disabilities Act <br />(ADA), Title III; Department of Justice Regulations of <br /> <br />99-06760 <br />ISSUED <br />10/07/1999 <br />04/04/2000 <br /> 5 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.