DWELLING PERMIT <br />DATE/TIME 11/05/99 14:41 <br />TYPE New Single Family Dwelling <br />OCCUPANCY R-3 <br />CONST TYPE V-N <br />UGB: SITE: FD <br /> <br />11, <br /> <br /> PERMIT NO 99-08359 <br /> STATUS ISSUED <br /> ISSUED 11/05/1999 <br /> TO EXPIRE 05/03/2000 <br /> PAGE 2 <br />STAIRWAYS shall not be less than 36 inches in clear width at <br />all points between the handrail height and the required <br />minimum headroom of 6 feet 8 inches. Minimum width from the <br />handrail down is 32 inches with one handrail, 28 inches with <br />two. The minimum required stair tread width is 9 inches. <br />The maximum stair rise is 8 inches. When risers are closed, <br />all treads less than 10 inches shall have a uniform nosing <br />betweem 3/4 inches and 1 1/4 inches. The greatest riser <br />height/tr'ead depth shall not exced th smallest by more than <br />3/8 inch, [Sec. 314.i: 314,2: 314.2.1: 314.3] <br />GUARDRAIL$. Porches, balconies or raised floor surfaces <br />located more than 30 inches above the floor or grade shall <br />have guardrails not less than 36 inches in height. Required <br />guardrail shall have intermediate rails or ornamental <br />closures which do not allow passage of an object 4 inches <br />or more in diameter. Horizontal spacing between the <br />vertical members in required gurardrails shall be a maximum <br />of 4 inches at the nearest point between the members. <br />[Sec. 315.3: 315.4] <br />GUARDRAILS AND HANDP~qILS shall be able to resist a single <br />concentrated load of 200 pounds applied in any direction at <br />any point along the top. [Table 301.4] <br />SMOKE DETECTORS shall be installed in each sleeping room, <br />outside of each separate sleeping area in the i~mediate <br />vicinity of the bedrooms and on each additional story of the <br />dwelling including basements. All detectors located outside <br />sleeping rooms shall be interconnected such that the <br />actuation of one alarm will actuate these alarms in the <br />individual unit and shall provide an alarm which will be <br />audible in all sleeping areas, Smoke detectors shall be <br />110 volt with batter back-up, [Sec. 316,1] <br />GARAGE/CARPORT FLOOR, That area of floor used for the <br />~arking of automobiles or other vehicles shall be sloped to <br />acilitate the movement of liquids to a drain or toward the <br />main vehicle entry doorway, [Sec, 309,3] <br />THE GARAGE shall be separated from the dwelling and its <br />attic area by means of 1/2 inch gypsum board applied to the <br />garage side of the wall. Where the separation is a floor- <br />ceiling assembly, the structure supporting the separation <br />shall be protected by 1/2 inch gypsum board or equivalent, <br />The door between the garage and residence shall De equipped <br />with solid wood doors not less than 1 2/8 inches in thick- <br />ness or 20-minute fire-rated, or equivalent, <br />[Sec. 309.1, 309.2] <br /> <br />12, <br /> <br />12. <br /> <br />14. <br /> <br />15, <br /> <br />16, <br /> <br /> <br />