Laserfiche WebLink
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />11/16/99 08:35 PERMIT NO <br />New Commercial STATUS <br />S-5 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />99-08079 <br />ISSUED <br />11/16/1999 <br />05/14/2000 <br /> 2 <br /> <br />REQUIRED SETBACKS: <br /> 1. <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br /> Front: Left: Right: Rear: <br /> ok as per site plan <br /> <br /> CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br /> THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 11/08/99, <br /> Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> PLAN REVIEW COVERAGE. <br /> This is a Plan Review covering the construction of the above <br /> indicated new building, <br /> Plans have been reviewed for compliance with the provisions <br /> of the Oregon Structural Specialty Code, 1998 Edition <br /> ('97 UBC). <br /> <br /> BUILDING CODE SUMMARY. <br /> Occupancy Classification: S-5 <br /> Type of Construction: II-N <br /> Basic Allowable Area: 12,000 sf <br /> Proposed Area: 22,330 sf <br /> Maximum Height in Feet: 55 ft <br /> Proposed Height: 29 ft (+/-) <br /> Maximum Number of Stories: 2 <br /> Proposed Number of Stories: 1 <br /> Building Yards: <br /> North: 100' to Hangar D East: 20' to Property Line <br /> South: On Property Line West: 1' to Property Line <br /> AREA SEPARATION WALL. (OSSC Sec 504.6) <br /> The plans submitted show a 2-hour area separation wall. <br /> The location of the area separation wall will create two <br /> separate buildings with the following floor araes: <br /> <br /> Hangar E (a): 12,000 sq ft <br /> Hangar E (b): 10,330 sq ft <br /> TOTAL: 22,330 SQ FT <br /> <br /> Reference Site Plan attached to front of plans, <br /> <br /> AREA SEPARATION WALLS. (OSSC Sec 504.6.1i <br /> Each portion of a buidling separated by one or more area <br /> separation walls that comply with the provisions of this <br /> section may be considered a separate building, The extent <br /> and location of such area separatiion walls shall provide <br /> separation. <br /> Area separation walls shall not be less than two-hour fire- <br /> resistive construction in Type II-N buildings. <br /> All openings shall be protected by a fire assembly having a <br /> one- and one-half-hour fire-protection rating in two-hour <br /> fire-resistive walls. <br /> <br /> AREA SEPARATION WALL TERMINATION. (OSSC Sec 506,64i <br /> Area separation walls shall extent vertical fro~ the <br /> foundation to a point at least 30 inches above the roof. <br />· EXCEPTIONS: <br /> 1. Any area separation wall may terminate at the underside <br /> of the roof sheathing, deck or slab, provided the roof- <br /> ceiling assembly is of at least two-hour fire-resistive <br /> construction. <br /> 2. Two-hour area separation walls may terminate at the <br /> underside of the roof sheathing, deck or slab, provided <br /> 2,1 When the roof-ceiling framing elements are parallel <br /> to the walls, such framing and elements supporting <br /> <br />Special: <br /> <br /> <br />