My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1619836
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1619836
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2013 10:57:09 AM
Creation date
4/6/2005 7:24:11 AM
Metadata
Fields
Template:
Permits
Permit Address
14302 STENBOCK WY NE
Permit City
Aurora
Permit Number
555-99-08079
Parcel Number
041W02D 60001
Permit Type
BUILD
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br />BUILDING PERMIT <br /> <br />11/16/99 08:35 PERMIT NO <br />New Commercial STATUS <br />S-5 ISSUED <br />II-N TO EXPIRE <br /> PAGE <br /> <br />99-08079 <br />ISSUED <br />11/16/1999 <br />05/14/2000 <br /> 2 <br /> <br />REQUIRED SETBACKS: <br /> 1. <br /> <br /> PLAN REVIEW COMMENTS AND CONDITIONS <br /> <br /> Front: Left: Right: Rear: <br /> ok as per site plan <br /> <br /> CALL BEFORE YOU DIG .... IT'S THE LAW. <br /> ATTENTION: Oregon law requires you to follow rules adopted <br /> by the Oregon Utility Notification Center. Those rules are <br /> set forth in OAR 952-001-0010 through OAR 952-001-0090. You <br /> may obtain copies of the rules by calling the center, <br /> (Note: The telephone number for the Oregon Utility Notifica- <br /> tion Center is (503) 232-1987), <br /> THIS PLAN REVIEW WAS COMPLETED BY M. JONES ON 11/08/99, <br /> Approval of submitted plans is not an approval of omissions <br /> or oversights by this office or of noncompliance with any <br /> applicable regulations of local government. <br /> PLAN REVIEW COVERAGE. <br /> This is a Plan Review covering the construction of the above <br /> indicated new building, <br /> Plans have been reviewed for compliance with the provisions <br /> of the Oregon Structural Specialty Code, 1998 Edition <br /> ('97 UBC). <br /> <br /> BUILDING CODE SUMMARY. <br /> Occupancy Classification: S-5 <br /> Type of Construction: II-N <br /> Basic Allowable Area: 12,000 sf <br /> Proposed Area: 22,330 sf <br /> Maximum Height in Feet: 55 ft <br /> Proposed Height: 29 ft (+/-) <br /> Maximum Number of Stories: 2 <br /> Proposed Number of Stories: 1 <br /> Building Yards: <br /> North: 100' to Hangar D East: 20' to Property Line <br /> South: On Property Line West: 1' to Property Line <br /> AREA SEPARATION WALL. (OSSC Sec 504.6) <br /> The plans submitted show a 2-hour area separation wall. <br /> The location of the area separation wall will create two <br /> separate buildings with the following floor araes: <br /> <br /> Hangar E (a): 12,000 sq ft <br /> Hangar E (b): 10,330 sq ft <br /> TOTAL: 22,330 SQ FT <br /> <br /> Reference Site Plan attached to front of plans, <br /> <br /> AREA SEPARATION WALLS. (OSSC Sec 504.6.1i <br /> Each portion of a buidling separated by one or more area <br /> separation walls that comply with the provisions of this <br /> section may be considered a separate building, The extent <br /> and location of such area separatiion walls shall provide <br /> separation. <br /> Area separation walls shall not be less than two-hour fire- <br /> resistive construction in Type II-N buildings. <br /> All openings shall be protected by a fire assembly having a <br /> one- and one-half-hour fire-protection rating in two-hour <br /> fire-resistive walls. <br /> <br /> AREA SEPARATION WALL TERMINATION. (OSSC Sec 506,64i <br /> Area separation walls shall extent vertical fro~ the <br /> foundation to a point at least 30 inches above the roof. <br />· EXCEPTIONS: <br /> 1. Any area separation wall may terminate at the underside <br /> of the roof sheathing, deck or slab, provided the roof- <br /> ceiling assembly is of at least two-hour fire-resistive <br /> construction. <br /> 2. Two-hour area separation walls may terminate at the <br /> underside of the roof sheathing, deck or slab, provided <br /> 2,1 When the roof-ceiling framing elements are parallel <br /> to the walls, such framing and elements supporting <br /> <br />Special: <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.