My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BUILD - 1619836
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
99-XXXXX
>
BUILD - 1619836
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2013 10:57:09 AM
Creation date
4/6/2005 7:24:11 AM
Metadata
Fields
Template:
Permits
Permit Address
14302 STENBOCK WY NE
Permit City
Aurora
Permit Number
555-99-08079
Parcel Number
041W02D 60001
Permit Type
BUILD
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DATE/TIME <br />TYPE <br />OCCUPANCY <br />CONST TYPE <br />UGB: SITE: <br /> <br /> BUILDING PERMIT <br /> 11/16/99 08:35 PERMIT NO <br /> New Commercial STATUS <br /> S-5 ISSUED <br /> II-N TO EXPIRE <br /> PAGE <br /> such framing shall not be less than one-hour fire- <br /> resistive construction for a width of not less than <br /> 5 feet on each side of the wall. <br /> 2.2 When roof-ceiling framing elements are not parallel <br /> to the wall, the entire span of such framing and <br /> elements supporting such framing shall not be of less <br /> than one-hour fire-resistive construction. <br /> 2.3 Openings in the roof shall not be located within <br /> 5 feet of the area separation wall. <br /> 2.4 The entire building shall be provided with not less <br /> than a Class B roof assembly as specified in <br /> TABLE 15-A. <br /> 3, Two-hour area separation walls may terminate at the <br /> underside of noncombustible roof sheathing, deck or <br /> slabs of roofs of noncombustible construction, provided <br /> 3.1 Openings in the roof are not located within 5 feet of <br /> the area separation wall. <br /> 2.2 The entire building is provided with not less than a <br /> Class B roofing assembly as specified in TABLE i5-A. <br />11. LOCATION ON PROPERTY, (OSSC Sec 503) <br /> Exterior walls shall have fire resistance and opening <br /> protection as set forth in TABLE 5-A and in accordance with <br /> such additional provisions as are set forth in Chapter 6, <br /> <br /> As per TABLE 5-A for a S-5 Occupancy of II-N Construction: <br /> Exterior walls: <br /> One-hour Noncombustible construction less than 20 feet. <br /> Openings: <br /> Not permitted less than 5 feet: Protected less than 20 <br /> feet with a fire assembly rating of three-fourths hour, <br /> <br />12. GROUP S, DIVISION 5 OCCUPANCY DEFINED. (OSSC Sec 211i <br /> Aircraft hangars where work is limited to exchange of parts <br /> and maintenance requiring no open flame or welding and <br /> helistops, <br /> <br />13. SPECIAL HAZARDS. (OSSC Sec 311.8i <br /> Storage and use of flammable and combustible liquids shall <br /> be in accordance with the Fire Code. <br /> Devices generating a glow, spark or flame capable of <br /> igniting flammable vapors shall be installed such that <br /> sources of ignition are at least 18 inches above the floor <br /> of any room in which Class I flammable liquids or flammable <br /> gases are used or stored, <br /> <br /> FIRE FLOW, (OUFC Sec 903i <br /> An approved water supply capable of supplying the required <br /> fire flow for fire protection shall be provided to all premi <br /> ~rimises uopn which buildings ~re constructed within the <br /> urisdiction, When any portion of the facility or building <br /> protected in excess of 150 feet from a water supply on a <br /> public street, as measured by an approved route around the <br /> exterior of the of the building, on-site fire hydrants and <br /> mains capable of supplying the required fire flow shall be <br /> provided when required by the chief. In setting the require- <br /> ments for fire flow, the chief may be guided by Appendix 3-A <br /> <br /> FIRESAFETY DURING CONSTRUCTION. (OUFC Sec 8704i <br /> Buildings under construction shall be in accordance with <br /> Article 87, <br /> Fire department access roads shall be established and main- <br /> tained in accordance with Section 902. <br /> Combustible debris shall not be accumulated within buildings <br /> Combustible debris, rubbish and waste material shall be <br /> ~emoved from buildings as often as practical. Combustible <br /> debris, waste material and trash shall not be burned on the <br /> site unless approved. <br /> <br /> ACCESSIBILITY, (OSSC Sec 1101i <br /> This site, building and facilities are required to be <br /> accessible to and useable persons with disabilities. <br /> Details and dimensions not shown on the plans shall comply <br /> <br />14. <br /> <br />15. <br /> <br />16, <br /> <br />99-08079 <br />ISSUED <br />11/16/1999 <br />05/14/2000 <br /> 3 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.