Detroit Dam and Reservoir Minto Fish Collection Facility Rebuild <br /> 2.5.3 RV Sewer Inlet <br /> Provide and install standard RV sewer inlet opening at the Site Host <br /> Structure to the sewer line as required. Standard inlet sewer hook-up <br /> connector to be installed shall provide both push in RV sewer hose and <br /> threaded hose connection. Provide a compatible cap or plug for the inlet <br /> opening when the inlet is not being used. <br /> 2.5.4 RV Sewer Hose and Hose Support <br /> Provide a heavy duty sewer hose kit and hose support system for the Site <br /> Host RV. Hose kit shall be the Camco Rhinoflex RV Sewer Kit which includes <br /> 15 feet of Rhinoflex sewer hose with swivel fittings, caps, elbow and <br /> 4-in-1 adapter sewer opening adapter, or an approved equal. The hose <br /> support system provided shall be the Blueline ® Aqueduct 10 Hose Support <br /> and Storage System, or an approved equal. <br /> 2.6 AIR RELEASE VALVE ASSEMBLY <br /> Provide an air release valve at the high points in pressure collection <br /> lines to liberate excess air. Air Release assembly shall be Orenco ARB05 <br /> or an approved equal. Air release valves shall be protected with insulated <br /> vault. <br /> PART 3 EXECUTION <br /> 3.1 INSTALLATION OF PIPELINES, TANKS, AND APPURTENANT CONSTRUCTION <br /> 3.1.1 General Requirements for Installation of Pipelines <br /> These general requirements apply except where specific exception is made in <br /> the paragraph entitled Special Requirements. <br /> 3.1.1.1 Location <br /> The work covered by this section shall terminate at a point approximately 5 <br /> feet from the building. Where the location of the sewer is not clearly <br /> defined by dimensions on the drawings, do not lay sewer line closer <br /> horizontally than 10 feet to a water main or service line. Install <br /> pressure sewer lines beneath water lines only, with the top of the sewer <br /> line being at least 2 feet below bottom of water line. Where sanitary <br /> sewer lines pass above water lines, encase sewer in concrete for a distance <br /> of 10 feet on each side of the crossing, or substitute rubber-gasketed <br /> pressure pipe for the pipe being used for the same distance. Where <br /> sanitary sewer lines pass below water lines, lay pipe so that no joint in <br /> the sewer line will be closer than 3 feet, horizontal distance, to the <br /> water line. <br /> a. Sanitary piping installation parallel with water line: <br /> (1) Normal conditions: Sanitary piping shall be laid at least 10 <br /> feet horizontally from a water line whenever possible. The <br /> distance shall be measured edge-to-edge. <br /> (2) Unusual conditions: When local conditions prevent a <br /> horizontal separation of 10 feet, the sanitary piping may be laid <br /> closer to a water line provided that: <br /> 33 30 00.00 25-8 <br />