My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9084344
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
12-XXXXX
>
9084344
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2020 11:55:21 AM
Creation date
1/3/2020 2:38:40 PM
Metadata
Fields
Template:
Permits
Permit Address
34939 NORTH SANTIAM HY SE
Permit City
GATES
Permit Number
555-12-06306
Parcel Number
094E29 00600
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Det_ci_ :am. and n_r oir Minco Sia_`. Cclleotrsn _aor-LC( 32s__11 <br /> will produce compression throughout remote end. <br /> b. Deflection measuring device: Sensitive to 1.0 percent of the <br /> diameter of the pipe being tested and shall be accurate to 1.0 percent <br /> of the indicated dimension. Deflection measuring device shall be <br /> approved prior to use. <br /> c. Pull-through device procedure: Pass the pull-through device <br /> through each run of pipe, either by pulling it through or flushing it <br /> through with water. If the device fails to pass freely through a pipe <br /> run, replace pipe which has the excessive deflection and completely <br /> retest in same manner and under same conditions. <br /> d. Deflection measuring device procedure: Measure deflections through <br /> each run of installed pipe. If deflection readings in excess of 4.5 <br /> percent of average inside diameter of pipe are obtained, retest pipe by <br /> a run from the opposite direction. If retest continues to show a <br /> deflection in excess of 4.5 percent of average inside diameter of pipe, <br /> replace pipe which has excessive deflection and completely retest in <br /> same manner and under same conditions. <br /> 3 .2.3 Tests for Pressure Lines <br /> Test pressure lines in accordance with the applicable standard specified in <br /> this paragraph, except for test pressures. For hydrostatic pressure test, <br /> use a hydrostatic pressure 50 psi in excess of the maximum working pressure <br /> of the system, but not less than 100 psi, holding the pressure for a period <br /> of not less than one hour. For leakage test, use a hydrostatic pressure <br /> not less than the maximum working pressure of the system. Leakage test may <br /> be performed at the same time and at the same test pressure as the pressure <br /> test. Test PVC plastic pressure lines in accordance with the requirements <br /> of AWWA C605 for pressure and leakage tests, using the allowable leakage <br /> given therein. <br /> -- End of Section -- <br /> 33 30 00 . 00 25-14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.