Laserfiche WebLink
7908 Stone Field Ct. SE, Aumsville <br />october 15, 1993 <br />Page 2 <br /> <br />10. <br /> <br />ll. <br /> <br />12. <br /> <br />13. <br /> <br />14. <br /> <br />15. <br /> <br />17. <br /> <br />Foundation plates shall be bolted to the foundation with minimum <br />1/2 inch diameter by 10 inch anchor bolts embedded at least 7 inches <br />into concrete or reinforced masonry and spaced not more than 6 feet <br />apart with a minimum of 2 bolts per piece with one bolt within 12 inches <br />of the end of each piece. Figure (R-303) <br /> <br />There is a 14,462# concentrated load from a girder truss at the interior <br />wall between the utility room and the study/bedroom #2. Provide a 42" <br />square footing x 12" deep with rebar ran each way, 3" up from the bottom <br />of the footing. <br /> <br />Provide a 4x8 DF #2 solid wood column to support the 14,462~ noted above <br />in Item #9. A multiple wood member column is not acceptable without the <br />engineering for the connections to transfer the load to all men, ers. <br /> <br />see the floor plan for additional locations for increased sizes of <br />required columns for girder truss loads. <br /> <br />Firestopping shall be provided in the following locations: in concealed <br />spaces of stud walls at the ceiling, floors, soffits, drop ceilings, <br />between stair stringers and at openings around vents, pipes, ducts, <br />chimneys and fireplaces at ceiling and floor spaces. (R-402.7) <br /> <br />Every sleeping room shall have at least one operable window approved for <br />emergency egress or rescue. The window sill height shall not be more <br />than 44 inches above the floor. The minimum net clear opening width <br />dimension shall be 20 inches. The minimum net opening height shall be <br />24 inches. The minimum net clear opening area shall be at least 5.7 <br />square feet. (R-210.2) <br /> <br />The garage shall be completely separated from the residence and its <br />attic area by means of 1/2-inch gypsum board or equivalent applied to <br />the garage side. The door between the garage and residence shall be <br />equipped with solid wood doors not less than 1 3/8 inches in thickness <br />or 20-minute fire rated, or equivalent. (R-209.2) <br /> <br />Heating and cooling appliances located in a garage shall be protected <br />from impact by automobiles. Appliances that generate a glow, spark of <br />flame capable of igniting gasoline vapors located in a garage shall be <br />installed with burners, burner ignition devices or heating elements and <br />switches at least 18 inches above the floor level. (M-1006.3) <br /> <br />Water heaters having nonrigid water connections and over 4-feet in <br />height from the base to the top of the tank case shall b~ anchored or <br />strapped to the building to resist horizontal displacement due to <br />earthquake motion. (M-1006.2) <br /> <br />In new construction, required smoke detectors shall receive their <br />primary power from the building wiring and when primary power is <br />interrupted, shall receive power from a battery. <br /> <br />Wood framed walls less than four feet in width at garage door openings <br />shall be provided with approved hold-down anchors. Anchors are to be <br />provided at each end of each wall segment and connect the wall studding <br />to the concrete foundation. As an alternate, a designed structural <br />system to resist the required 80 mile per hour wind load can be <br />provided. <br /> <br />"APPROVED." only when this sheet is attached to plans <br /> <br /> <br />