My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permit - 1283712
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
93-XXXXX
>
Permit - 1283712
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2011 10:12:55 AM
Creation date
9/3/2003 4:00:47 PM
Metadata
Fields
Template:
Permits
Permit Address
130-160 3RD ST
Permit City
Aumsville
Permit Number
93-02861
Permit Type
Permit
Permit Doc Type
Permit Document
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
130, 140, 150, 160 3rd St., <br />September iS, 1993 <br /> <br />10. <br /> <br />11. <br /> <br />12. <br /> <br />13. <br /> <br />14. <br /> <br />projection of adjacent $Z~ad~. The*~argest,tread run Ox riser height <br />within any flight of stairs ~all ~o~ ex~e~d the smallest by more than <br />3/8 inch. (3306(c)) <br /> <br />Stairways shall have handrails on each side. The hand grip portion of <br />handrails shall be not less than 1 1/2 inches nor more than 2 inches in <br />croSs-sectional dimension or the shape shall provide a~ equivalent <br />gripping surface. Handrails shall be between 34 and 38 inches above the <br />nosing of treads. They shall be continuous the full length of the <br />stairs. Ends shall extend not less than 6 inches beyond the top and <br />bottom risers and be returned or terminate in newel posts or safety <br />terminals. (3306(i)) <br /> <br />open sides of stairways and landings mor~ than 30 inches above grade <br />shall be protected by a guardraii not less than 42 inches in height, <br />The top of guardrails for stairways, exclusive of their landings may <br />have a height as specified in Section 3306(j) for handrails. (Not less <br />than 34 inches nor more than 38 inches.) Open stair railings and <br />guardrails shall have intermediate rails or an ornamental pattern such <br />that an object 4 inches in diameter cannot pass through. (12 inch <br />diameter sphere where a stairway for a commercial or industrial-type <br />occupancy is not accessible to the public.) (1712) <br /> <br />Dwelling units, congregate residences and hotel or lodging house guest <br />rooms that are used for sleeping purposes shall be provided with smoke <br />detectors. Detectors shall be installed in accordance with the approved <br />manufacturer's instructions. (1210(a)(1)) <br /> <br />In dwelling units, a detector shall be installed in sash sleeping room <br />and at a point centrally located in the corridor or area giving access <br />to each separate sleeping area. (1210(a)(4)) <br /> <br />In new construction, required smoke detectors shall receive their <br />primary power from the building wiring when such wiring is served from a <br />com~ercial source and shall be equipped with a battery backyp. The <br />detector shall emit a signal when the batteries are low. Wiring shall <br />be permanent and without a disconnecting switch other than those <br />required for overcurrent protection. <br /> <br />Thi~ site, building and facilities are required to be accessible to and <br />useable by the physically handicapped. Details and dimensions not shown <br />shall comply with Public Law 101-336, the ~ericans with Disabilities <br />Act, Part III; Department of Justice Regulations of Friday, July 26, <br />199~; 28 C.F.R., ~art 36, including Anlericans with Disabilities Act <br />Accessibility Guidelines (ADAAG) and Public Law 100-430, the Fair <br />~ousing Act and the regulations adopted thereunder and the requirements <br />of Chapter 31. (3101) <br /> <br />Doors shall be capable of opening so that the clear width of the opening <br />is not less than 32 inches. (3109(i)(2)) <br /> <br />Ail Group R, Division i apartment Occupancies shall have adaptable <br />dwelling units. <br /> <br />Water heaters shall be anchored or strapped to resist horizontal <br />displacement due to earthquake motion. (UPC 1310(e)) <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.