My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12987539
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
17-XXXXXX
>
12987539
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2025 8:00:12 PM
Creation date
7/30/2025 4:41:38 PM
Metadata
Fields
Template:
Permits
Permit Address
13773 SILVER FALLS HWY SE
Permit City
Sublimity
Permit Number
555-17-005840-STR
Parcel Number
081W14 00600
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TFP37O <br /> Page 12 of 12 <br /> kW Inadvertent operation of only the linear has been established, use the call- The owner Is responsible for the <br /> detection or an automatic sprinkler, brated gauge to determine the standard inspection,testing,and maintenance of <br /> (e.g., incidental damage or malicious air pressure gauge deviation(if any)and their fire protection system and devices <br /> activity), will not allow water flow into note the calibration deviation between in compliance with this document,as <br /> the system.Not allowing water to flow the calibrated gauge and the standard well as with the applicable standards of <br /> in these cases is desirable for refriger- gauge for future reference. the National Fire Protection Association <br /> ated spaces. (e.g., NEPA 25), in addition to the <br /> Dry System Care and standards of any authorities having <br /> When the system is set for service, jurisdiction. Contact the Installing <br /> the system piping is pressurized with Maintenance QUELL licensee or product manufac- <br /> a dry source of air, and the releasing Curer with any questions. <br /> panel is in a normal standby condition. The TYCO QUELL Preaction and Dry Sprinkler systems designed by the <br /> In the event of a fire, the opening of Systems must be maintained and QUELL methodology are recom- <br /> one or more Ultra K17 sprinklers will serviced in accordance with this mended to be inspected,tested,and <br /> begin to relieve air pressure from section. maintained by a qualified Inspection <br /> the system piping. The Model QRS Before closing a fire protection system Service in accordance with local <br /> Electronic Accelerator will respond to main control valve for maintenance requirements and/or national codes. <br /> an air decay rate of at least 0.1 psisec work on the fire protection system that <br /> (0.007 bar/sec)to initiate Zone 1 of the it controls,permission to shut down the Limited <br /> releasing panel.With Zone 1 initiated, affected tire protection system must be <br /> the releasing panel will energize obtained from the proper authorities warrant <br /> y <br /> the releasing circuit to the solenoid and notify all personnel who may be <br /> valve in the DV-5 Deluge Valve trim. affected by this action. For warranty terms and conditions,visit <br /> Opening of the solenoid valve trips www.tyco-fire.00m. <br /> the DV-5 allowing water to enter the Absence of the outer piece of an <br /> system piping and flow to the activated escutcheon, which is used to cover • <br /> sprinklers. a clearance hole, can delay sprinkler Ordering <br /> operation in a fire situation. <br /> Installation The owner must assure that the sprin- Procedure <br /> klers are not used for hanging any When placing an order,indicate the full <br /> The TYCO QUELL Preaction and Dry objects and that the sprinklers are only product name. Refer to the price list <br /> Systems must be installed in actor- cleaned by means of gently dusting for a complete listing of part numbers <br /> ( dance With this section. with a feather duster;otherwise, non- (P/Ns)and system packages. <br /> • <br /> v Except as noted below,all components operation in the event re a fire or mad <br /> vertent be installed in accordance with vertent operation may result. Contact your local distributor for <br /> their applicable data sheet or installa- Sprinklers which are found to be availability. <br /> Lion manual. leaking or exhibiting visible signs of <br /> Valve Trim corrosion must be replaced. <br /> TFP1465 references the use of nominal Automatic sprinklers must never be <br /> air pressure of 15 psi (1,0 bar). The painted, plated, coated, or otherwise <br /> normal system air pressure for the altered after leaving the factory. <br /> QUELL Preaction or Dry System can Modified sprinklers must be replaced. <br /> be at any pressure compatible to the Sprinklers that have been exposed to <br /> Model ORS Electronic Accelerator(Ref. corrosive products of combustion,but <br /> Table D, Nominal Pressure column). have not operated,should be replaced <br /> The pressure relief valve in the trim is if they cannot be completely cleaned <br /> to be set at 10 psi(0,7 bar)higher than by wiping the sprinkler with a cloth or <br /> the nominal system air pressure being by brushing it with a soft bristle brush. <br /> used. Care must be exercised to avoid <br /> Air Pressure Gauge damage to the sprinklers before, <br /> During the system set-up acceptance during,and after installation.Sprinklers <br /> tests, a calibrated pressure gauge damaged by dropping,striking,wrench <br /> should be used to set the system air twist/slippage, or the like, must be <br /> pressure that had been entered into the replaced. Also, replace any sprinkler <br /> SprinkFDT-Q Fluid Delivery Calculation that has a cracked bulb or that has lost <br /> Program.After the proper air pressure liquid from its bulb.(Refer to Installation <br /> Section.) <br /> GLOBAL HEADQUARTERS 11000 Pennbrook Parkway,Lansdale,PA 190461 Telephone+1-215-362-0700 <br /> Copyright®2014 Tyco Fire Products,LP. All rights reserved. tgCo <br /> Fire Protection Producrs <br />
The URL can be used to link to this page
Your browser does not support the video tag.