My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12987539
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
17-XXXXXX
>
12987539
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2025 8:00:12 PM
Creation date
7/30/2025 4:41:38 PM
Metadata
Fields
Template:
Permits
Permit Address
13773 SILVER FALLS HWY SE
Permit City
Sublimity
Permit Number
555-17-005840-STR
Parcel Number
081W14 00600
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EX4991 March 2,2007 <br /> 06NK23629 <br /> �/ 1. Introduction <br /> For ceiling heights of 35 ft,40 ft, and 45 ft, the fire protection performance of the Tyco <br /> K-16.8 Control Mode Specific Application(CMSA) sprinkler sprinklers has only been <br /> evaluated in dry pipe systems for protection of rack storages of Class II and III <br /> commodities jl). <br /> The purpose of this program is to evaluate protection of 40 ft high Class III commodity <br /> storage in a 48 ft high building using a thy-pipe system and Tyco K-16.8 upright CMSP <br /> sprinklers rated at 286°F. The sprinkler spacing was at 10 ft by 10 ft and the sprinkler <br /> deflector to ceiling distance was 7 inch. The sprinkler discharge pressure was maintained <br /> at 30 psig with a discharge rate of 92 gpm per sprinkler. <br /> 2. Test Facility, Commodity and Storage Arrangements <br /> 2.1 Test Facility <br /> The fire tests were conducted in Underwriters Laboratories large-scale fife test facility <br /> located in Northbrook, Illinois. The large-scale fire test building used for this <br /> investigation houses four test areas that are used to develop data on the fire growth and <br /> fire suppression characteristics of commodities, as well as the fire protection performance <br /> ( of automatic water sprinkler systems. A schematic of the test facility is shown in Figure <br /> V 1. <br /> Mr Lil <br /> a <br /> r,r ADD Test Fatty <br /> I Lan Seals 111 El] <br /> nit tut Ready r ' <br /> �,,,.xaerupu Cstmpetv86DD <br /> PAPA T:,tFxdty <br /> 4oniitinny^'+> LL Phe[vyae <br /> Fran <br /> Figure 1.Test Facility <br /> The fire tests were conducted in a 120 ft.by 120 ft. by 54 ft. high room fitted with a 100 <br /> ft.by 100 ft. adjustable height ceiling, which can be set at various heights. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.