My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12989299
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
15-XXXXXX
>
12989299
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 8:00:14 PM
Creation date
7/31/2025 4:12:09 PM
Metadata
Fields
Template:
Permits
Permit Address
6792 SCISM RD NE
Permit City
Silverton
Permit Number
555-15-000086-DWL
Parcel Number
061W30B 01600
Permit Type
1 & 2 Fam Dwelling (New Only)
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRE AND SMOKE PROTECTION FEATURES <br /> • <br /> ways,ramps and exit passageways except as permitted by 2. In Group B and R occupancies equipped through- <br /> Sections 1022.4 and 1023.6,respectively. out with an automatic sprinkler system in accor- <br /> Exception: Fire dampers are not required at penetra- dance with Section 903.3.1.1,smoke dampers are <br /> lions of fire barriers where any of the following apply: not required at penetrations of shafts where: <br /> I. Penetrations are tested in accordance with ASTM 2.1. Kitchen, clothes dryer,bathroom and[oi- <br /> 1 119 or UL 263 as part of the fire-resistance- let room exhaust openings are installed <br /> • rated assembly. with steel exhaust subducts, having a <br /> minimum wall thickness of 0.0187-inch <br /> 2. Ducts are used as part of an approved smoke con- <br /> trol system in accordance with Section 909 and (0.4712 mm)(No. 26 gage); - <br /> where the use of a fire damper would interfere 2.2. The subducts extend at least 22 inches <br /> with the operation of a smoke control system. (559 ram)vertically;and <br /> 3. Such walls are penetrated by ducted HVAC sys- 2.3. An exhaust fan is installed at the upper <br /> tems, have a required fire-resistance rating of I terminus of the shaft that is powered con- <br /> hour or less, are in areas of other than Group H tinuously in accordance with the provi- <br /> and are in buildings equipped throughout with an sions of Section 909.11,so as to maintain <br /> automatic sprinkler system in accordance with a continuous upward airflow to the out- <br /> Section 903.3.1.1 or 903.3.1.2. For the purposes side. <br /> of this exception,a ducted HVAC system shall be 3. Smoke dampers are not required at penetration of <br /> a duct system for conveying supply, return or exhaust or supply shafts in parking garages that <br /> exhaust air as part of the structure's HVAC sys- are separated from other building shafts by not <br /> tem. Such a duct system shall be constructed of less than 2-hour fire-resistance-rated construe- <br /> sheet steel not less than No. 26 gage thickness tion. <br /> and shall be continuous from the air-handling 4. Smoke dampers are not required at penetrations <br /> appliance or equipment to the air outlet and inlet of shafts where ducts are used as part of an <br /> terminals. approved mechanical smoke control system <br /> 717.5.2.1 Horizontal exits. A listed smoke damper designed in accordance with Section 909 and <br /> designed to resist the passage of smoke shall be pro- where the smoke damper will interfere with the <br /> vided at each point a duct or air transfer opening pene- operation of the smoke control system. <br /> traces afire barrier that serves as a horizontal exit. 5. Fire dampers and combination fire/smoke damp- <br /> 717.5.3 Shaft enclosures. Shaft enclosures that are per- ers are not required in kitchen and clothes dryer <br /> witted to be penetrated by ducts and air transfer openings exhaust systems when installed in accordance <br /> shall be protected with approved fire and smoke dampers with the Mechanical Code. <br /> installed in accordance with their listing. 717.5.4 Fire partitions. Ducts and air transfer openings <br /> Exceptions: that penetrate fire partitions shall be protected with listed <br /> 1. Fire dampers are not required at penetrations of fire dampers installed in accordance with their listing. <br /> shafts where: Exceptions: In occupancies other than Group H,fire <br /> 1.1. Steel exhaust subducts are extended at dampers are not required where any of the following <br /> least 22 inches (559 mm) vertically in apply: <br /> exhaust shafts,provided there is a contin- 1. Corridor walls in buildings equipped throughout <br /> uous airflow upward to the outside;or with an automatic sprinkler system in accordance <br /> 1.2. Penetrations are tested in accordance with with Section 903.3.1.1 or 903.3.1.2 and the duct <br /> ASTM E 119 or UL 263 as part of the is protected as a through penetration in accor- <br /> fire-resistance-rated assembly;or dance with Section 714. <br /> 1.3. Ducts are used as part of an approved 2. Tenant partitions in covered and open mall build- <br /> smoke control system designed and ings where the walls are not required by provi- <br /> installed in accordance with Section 909 sions elsewhere in the code to extend to the <br /> and where the fire damper will interfere underside of the floor or roof sheathing, slab or <br /> with the operation of the smoke control deck above. <br /> system;or 3. The duct system is constructed of approved mate- <br /> 1.4. The penetrations are in parking garage rials in accordance with the Mechanical Code <br /> exhaust or supply shafts that are separated and the duct penetrating the wall complies with i <br /> from other building shafts by not less than all of the following requirements: <br /> 2-hour fire-resistance-rated construction. 3.1.The duct shall not exceed 100 square <br /> inches(0.06 m'). <br /> 2014 OREGON STRUCTURAL SPECIALTY CODE 149 <br />
The URL can be used to link to this page
Your browser does not support the video tag.