My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13007268
Images9
>
Public Works - Permits
>
Building
>
FOR PUBLIC VIEW ON INTERNET
>
COMPLETED FILES - INACTIVE
>
16-XXXXXX
>
13007268
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:00:18 PM
Creation date
8/6/2025 2:54:29 PM
Metadata
Fields
Template:
Permits
Permit Address
6150 KEIZER STATION BLVD NE
Permit City
Keizer
Permit Number
555-16-003812-STR
Parcel Number
063W36A 04200
Permit Type
Structural
Extra Information
Alternate Material(s) and/or Method(s)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
( AquaFlash® System DS494 <br /> A Liquid-Applied Transition Membrane for Sealing <br /> Rough Openings at Windows, Doors and Other Wall Penetrations <br /> Description AquaFlash Mesh: Ultraviolet Exposure: (AC148 <br /> AquaFlash Liquid is an extremely The mesh is available in both rolls Sec.4.4)-210 hrs-No deleterious <br /> flexible,water-based polymer and pre-fabricated corner pieces. effects when viewed under 5x <br /> material used in conjunction with Each roll is 180 If(54.9 m) in length magnification. <br /> AquaFlash Mesh and AquaFlash and packaged as follows: Accelerated Aging Prior to Water <br /> Corners, non-woven blend fabric, to 4 in(102 mm): 9 rolls/box Resistance: (AC148 Sec.4.5.2.2) <br /> seal substrates around windows, 6 in (152 mm): 6 rolls/box -25 cycles: 3 hrs at 120°F (49°C), <br /> doors and other openings. 9 in (229 mm): 4 rolls/box 3 hrs water immersion, 18 hrs air <br /> Uses The AquaFlash Corners are dry: No visible damage under 5x <br /> The AquaFlash System provides an available in 6 in (152.4 mm)widths magnification. <br /> effective,water-resistant transition (152 mm)and packaged 100/box. Water Resistance: (AATCC Method <br /> 127 and AC148 Sec.4.5)-No <br /> membrane to provide continuity of Working Time <br /> Dryvit's Backstop®NTT,/ air and AquaFlash Liquid provides a water leakage after UV exposure <br /> water-resistive barrier between working time similar to paint. The and accelerated aging cycling. <br /> different substrate materials and to product will not set-up in the pail. Pliability: (AC148 Sec.4.6) - No <br /> bridge across sheathing joints, at Keep unused material covered to cracking when bent over 1/8 in <br /> openings, at inside and outside prevent evaporation. Any surface (3 mm) mandrel at 32 °F(0°C). <br /> corners, as well as across floor skin should be removed prior to use. Acceptable Substrates: <br /> lines. Drying Time • Exterior grade gypsum sheathing <br /> Benefits The drying time of AquaFlash meeting ASTM C 1396 (formerly <br /> AquaFlash Liquid is used directly System is dependent upon the air C 79) requirements for water <br /> from the pail and can be applied temperature,wind conditions and resistant core or Type X core at <br /> using a brush or roller over relative humidity. Under average the lime of application <br /> approved, clean, dry substrates. drying conditions [70 °F(21 °C), • Exterior sheathing having a water- <br /> When applied in accordance with 55% R.H.], AquaFlash System will resistant core with fiberglass mat <br /> CI Dryvit recommendations, AquaFlash be dry in approximately 30 minutes facers meeting ASTM C 1177 <br /> • <br /> System can be exposed to weather on absorbent substrates and 1 1/2 Exterior fiber reinforced cement or <br /> longer than conventional flashing hours on non-absorbent substrates. calcium silicate boards <br /> tape prior to covering with a building • APA Exterior or Exposure 1 Rated <br /> cladding or siding. It is easy to Performance Requirements Plywood, Grade C-D or better, <br /> apply and fully compatible with The AquaFlash System has been nominal 1/2 in (12.7 mm), minimum, <br /> Dryvits Backstop®NTT" as well as evaluated in accordance with installed with the C face out <br /> all Dryvit adhesives. AquaFlash ICC ES AC148 Acceptance Criteria • APA Exterior or Exposure 1 Fire <br /> Corners are designed to be used to for Flashing Materials (Self-adhering Retardant Treated Plywood, <br /> reinforce window corners without Flashing)as follows: Grade C-D or better, nominal <br /> the need for field cutting and Tensile Strength: 1/2 in (12.7 mm), minimum, <br /> Forming. (ASTM D 5034 and AC148 installed with the C face out <br /> Sec.4.1)-Minimum 39.9 lb/in • APA Exposure 1 Rated Oriented <br /> Coverage and Packaging: (7.1 kg/cm)for aged specimen Strand Board(OSB) nominal <br /> AquaFlash Liquid: Material is Nail Sealability: (ASTM D 1970 and 1/2 in(12.7 mm), minimum <br /> supplied in 8 lb(3.6 kg) or 40 lb AC148 Sec.4.2)-No water • Unpainted, unsealed concrete and <br /> (18.2 kg)containers. See table penetration. CMU <br /> below for coverage. Accelerated Aging Prior to Peel • Galvanized metal and aluminum <br /> 4"Mesh 6"Mesh 9"Mesh Adhesion: (AC148 Sec. 4.3.1.1.1): Surface Preparation <br /> - — -25 cycles: 3 hrs at 120°F(49 CC), Substrate surfaces shall be sound, <br /> 38 If/lb 25 Ifnb 17 If/lb 3 hrs water immersion, 18 hrs at dry and free of foreign materials such <br /> (25.5 m/kg) (16.8 m/kg) (11.42 mhg) -40°F(-40 °C). No visible damage as dirt, dust, oil, paint,wax,water <br /> All coverages are approximate and under 5x magnification. repellents or other materials that <br /> depend upon substrate, details and Peel Adhesion: (ASTM D3330 and inhibit adhesion. The AquaFlash <br /> individual application technique. AC148 Sec. 4.3)-Peel strength of System can bridge substrate gaps up <br /> aged specimens exceeded 75%of to 1/4 in(6.4 mm). Larger gaps may <br /> control specimens. require special treatment. <br />
The URL can be used to link to this page
Your browser does not support the video tag.