Template:
Permits
Permit Address
10052 ENCHANTED WAY SE
Permit City
JEFFERSON
Permit Number
555-18-003782-PRMT
Parcel Number
093W02 00500
Permit Type
Septic
Permit Doc Type
Permit Document
Status
Ready to Film
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Workmanship <br /> The power supply to the new control panel will need to be a minimum 60A,240V,single-phase circuit <br /> (L1,L2,N,G)for the pumps and blower, and a minimum 20A, 120V,single-phase circuit(L1,N,G)for <br /> the controls and panel heater.A subpanel/breaker box may need to be mounted adjacent to the control <br /> panel to provide a means of disconnect.The Installer will need to coordinate with the facility to identify <br /> the power supply for the panel.The pump and control systems and related appurtenances shall be installed <br /> in accordance with the manufacturer's instructions,the approved plans,and all appropriate electrical <br /> codes.Placement,assembly,and installation shall be conducted to facilitate easy operation,maintenance, <br /> repair,removal and replacement.All components shall be clearly marked in a permanent and professional <br /> manner,consistent with the design,to facilitate identification,monitoring,and troubleshooting.The <br /> Installer shall retain a licensed electrician to extend the power supply to the control panel and will be <br /> responsible for obtaining the necessary electrical permits and inspections.Copies of all permits,inspection <br /> reports,panel diagrams,and drawings of any approved"as built"changes shall be provided to the <br /> Inspector by the Installer. <br /> 5_6 Subsurface Soil Absorption System -Standard Trenches <br /> Materials <br /> • Drain Media—Clean, washed, round rock meeting the criteria in OAR 340-071-0100(53) with a <br /> preference for uniformity biased toward the smaller end of the acceptable range(3/4-inch size)shall <br /> be durable and free of excess fines,or EZflow—Model 1202H-Geo. <br /> • Filter Fabric — Meeting the criteria in OAR 340-073-0041 to cover the drain media from one <br /> sidewall to the other and from the beginning to the end of each trench. <br /> • Standard Effluent Distribution Piping and Fittings-See Materials section under Piping and <br /> Plumbing. <br /> • Distribution Boxes—Manufactured as outlined in OAR 340-73-0035 and installed with tight pipe <br /> connections to minimize root intrusion and effluent exfiltration. <br /> Workmanship <br /> The Installer shall stake out the effluent distribution system and the routing of all related components prior <br /> ± . to initiating construction.Any obstacles,non-conforming grades,or other factors that would prohibit <br /> installation or modify locations shall be flagged for review with the Designer.Any modifications will <br /> require approval by the Designer.Drawings of any approved"as built"changes noting pertinent <br /> dimensions,reference points,and elevations shall be provided to the Inspector by the Installer. <br /> The bottom of each drainfield trench and the distribution piping shall be level within a tolerance of plus or <br /> minus one inch from the point of beginning(point where the distribution header is connected to the <br /> distribution box).Total trench depth shall be within the minimum and maximum limits shown on the <br /> approved plans.Raking of the bottom and sidewalls of the trenches may be necessary to remove smearing <br /> created during excavation.Roots greater than'/2-inch in diameter shall be cut at the edge of the excavation <br /> and removed. <br /> The drain media or EZ flow shall be placed in the trenches in a manner that minimizes compaction, <br /> disturbance, and sloughing of sidewall soils or spoils.The top surface of the drain rock shall be level. <br /> Drain media shall be covered with filter fabric prior to inspection.Monitoring ports shall be installed as <br /> shown on the plans. <br /> CES-Albany,OR St.Innocent Winery and Tasting Room I P&S <br /> Doc:2018240028 St.Innocent Winery Plans&Specs May 2018 I Page 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.